HGLTF Turbine Flow Meter

 

Product name: Turbine Flow Meter
Application: used for volumetric flow measurement of liquids

 

Advantages: fast delivery, customer made, sample acceptable, OEM acceptable


Tel: 86-517-86885008

Email: sales@hginstrument.com

Enquiry

Product Description

Liquid Turbine Flow Meter

Service: Liquid, gas or steam
Meter size: Flange/wafer connection type: DN25 - DN300
Insertion type: DN150 – DN2000
Wetted material option: SS304, SS316
Operation temperature ≤ 250℃
Accuracy: 1.0 % - 1.5%
Digital display: instantaneous flow and accumulative flow
Output: 4-20mA, pulse (RS485 and HART optional)
Built-in Temperature and Pressure compensation for gas or steam

 

Technical Parameters

  1.     Basic Parameters

                                                                   Table 1

Instrument Diameter (mm) & Connection

4, 6, 10, 15, 20, 25, 32, 40 thread connection

(15, 20, 25, 32, 40) 50, 65, 80, 100, 125, 150, 200 flange connection

Accuracy

±1%,  ±0.5%,  ±0.2% (need special order)

Turndown

1:10, 1:15; 1:20

Instrument Material

SS304, SS316 (L)

Medium Temperature

-20 to +120 Degree C

Ambient Conditions

Temperature -10 to 55 C, relative humidity 5% to 90%, atmospheric pressure 86 to 106 KPa

Output Signal

Sensor: pulse frequency signal, low electrical level≤0.8V,high level≥8V

Transmitter: two wire, 4-20 mA DC current signal

Power Supply

Sensor: +12V DC, +24V DC (optional)

Transmitter: +24V DC

Local indication type: built-in 3V lithium cell or +24VDC external

Signal Transmission Wire

STVPV3×0.3 (3 wire), 2×0.3 (2 wire)

Transmission Distance

No more than 1000 m

Signal Line Interface

Basic type: Hausman connector or 3-core wire;

Explosion-proof type: M20 × 1.5 (F)

Explosion Proof

Basic type: non-explosion proof; explosion proof type: ExdIIBT6

Enclosure Protection

IP65

 

  1.     Measuring Range & Pressure

                                                                 Table 2

Instrument Diameter (mm)

Normal

Flow Range (m3/h)

Extended Flow Range (m3/h)

Normal Connection & Pressure Rating

Special Pressure Rating(MPa)

(Flange Connection)

DN 4

0.04 ~ 0.25

0.04 ~ 0.4

Thread connection/6.3MPa

10, 16, 25

DN 6

0.1 ~ 0.6

0.06 ~ 0.6

Thread connection/6.3MPa

10, 16, 25

DN10

0.2 ~ 1.2

0.15 ~ 1.5

Thread connection/6.3MPa

10, 16, 25

DN15

0.6 ~ 6

0.4 ~ 8

Thread connection/6.3MPa

4.0, 6.3, 10, 16, 25

Flange connection/2.5MPa

DN20

0.8 ~ 8

0.45 ~ 9

Thread connection/6.3MPa

4.0, 6.3, 10, 16, 25

Flange connection/2.5MPa

DN25

1 ~ 10

0.5 ~ 10

Thread connection/6.3MPa

4.0, 6.3, 10, 16, 25

Flange connection/2.5MPa

DN32

1.5 ~ 15

0.8 ~ 15

Thread connection/6.3MPa

4.0, 6.3, 10, 16, 25

Flange connection/2.5MPa

DN40

2 ~ 20

1 ~ 20

Thread connection/6.3MPa

4.0, 6.3, 10, 16, 25

Flange connection/2.5MPa

DN50

4 ~ 40

2 ~ 40

Flange connection/2.5MPa

4.0, 6.3, 10, 16, 25

DN65

7 ~ 70

4 ~ 70

Flange connection/2.5MPa

4.0, 6.3, 10, 16, 25

DN80

10 ~ 100

5 ~ 100

Flange connection/2.5MPa

4.0, 6.3, 10, 16, 25

DN100

20 ~ 200

10 ~ 200

Flange connection/2.5MPa

4.0, 6.3, 10, 16, 25

DN125

25 ~ 250

13 ~ 250

Flange connection/1.6MPa

2.5, 4.0, 6.3, 10, 16

DN150

30 ~ 300

15 ~ 300

Flange connection/1.6MPa

2.5, 4.0, 6.3, 10, 16

DN200

80 ~ 800

40 ~800

Flange connection/1.6MPa

2.5, 4.0, 6.3, 10, 16

 

Site Installation

Company introduction