{"id":1884,"date":"2021-08-25T17:30:24","date_gmt":"2021-08-25T09:30:24","guid":{"rendered":"http:\/\/201230ip92c2.adwebcloud.com\/?post_type=product&#038;p=1884"},"modified":"2021-10-12T14:27:24","modified_gmt":"2021-10-12T06:27:24","slug":"hg12d-c-conductivity-electrode","status":"publish","type":"product","link":"https:\/\/www.hginstrument.com\/es\/analysis-instrument\/hg12d-c-conductivity-electrode\/","title":{"rendered":"HG12D-C Electrodo de conductividad"},"content":{"rendered":"<p><strong>Feature:<\/strong><br \/>\n\u25cf Conductivity probe consists of two alloy rings round with coil, which is enclosed in the plastic ring, so the conductivity probe does not contact the measured liquid, no need of frequent maintenance.<br \/>\n\u25cf Avoid the problem of ion deposition, coverage or polarization. Oil contamination or pollution does not affect the inductance type electrode&#8217;s performance.<br \/>\n\u25cf Service life can reach about 10 years.<br \/>\n\u25cf Built-in special integrated circuit, directly output voltage, 4-20mA and RS485 digital signal.<br \/>\n\u25cf It can be used to match with conductivity transmitter or directly connect to PLC or DCS<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Datos t\u00e9cnicos:<\/strong><\/p>\n<table width=\"697\">\n<tbody>\n<tr>\n<td style=\"background-color: #d8d8d8; vertical-align: middle;\" width=\"277\">Measuring principle<\/td>\n<td width=\"420\">Inductance type<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #d8d8d8; vertical-align: middle;\">Wetted material<\/td>\n<td width=\"420\">PP,\u00a0 PFA (optional)<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #d8d8d8; vertical-align: middle;\">Rango de medici\u00f3n<\/td>\n<td width=\"420\">0 ~ 2 mS\/cm;\u00a0 0 ~ 20 mS\/cm;<br \/>\n0 ~ 200 mS\/cm;\u00a0 0 ~ 2000 mS\/cm\u00a0 ( optional )<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #d8d8d8; vertical-align: middle;\">Temperatura de funcionamiento<\/td>\n<td>100\u2103<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #d8d8d8; vertical-align: middle;\">Presi\u00f3n de funcionamiento<\/td>\n<td>1.0 Mpa,\u00a0 2.5Mpa<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #d8d8d8; vertical-align: middle;\">Temperature compensation option<\/td>\n<td>Pt100 or customize<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #d8d8d8; vertical-align: middle;\">Se\u00f1al de salida<\/td>\n<td>0 ~ 2000 mV,\u00a0 4 ~ 20mA ( Load \u2264 500\u03a9 ), RS485 (optional)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>Appearance &amp; dimension:\u00a0<\/strong><\/p>\n<table width=\"729\">\n<tbody>\n<tr style=\"background-color: #d8d8d8;\">\n<td style=\"text-align: center;\" width=\"218\">Tipo<\/td>\n<td style=\"text-align: center;\" width=\"254\">Picture<\/td>\n<td style=\"text-align: center;\" width=\"257\">Dimension<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\">Type 1<\/td>\n<td>\u3000<img class=\"wp-image-1878 aligncenter\" src=\"http:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/08\/hg12d-c-02.jpg\" alt=\"hg12d c 02\" width=\"172\" height=\"407\" srcset=\"https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/08\/hg12d-c-02.jpg 227w, https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/08\/hg12d-c-02-127x300.jpg 127w\" sizes=\"(max-width: 172px) 100vw, 172px\" \/><\/td>\n<td>\u3000<img class=\"wp-image-1875 size-full aligncenter\" src=\"http:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/08\/dimension-01-3.jpg\" alt=\"dimension 01 3\" width=\"407\" height=\"404\" srcset=\"https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/08\/dimension-01-3.jpg 407w, https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/08\/dimension-01-3-150x150.jpg 150w, https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/08\/dimension-01-3-300x298.jpg 300w, https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/08\/dimension-01-3-100x100.jpg 100w\" sizes=\"(max-width: 407px) 100vw, 407px\" \/><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\">Type 2<\/td>\n<td>\u3000<img class=\"wp-image-1879 aligncenter\" src=\"http:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/08\/hg12d-c-03.jpg\" alt=\"hg12d c 03\" width=\"137\" height=\"414\" srcset=\"https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/08\/hg12d-c-03.jpg 200w, https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/08\/hg12d-c-03-99x300.jpg 99w\" sizes=\"(max-width: 137px) 100vw, 137px\" \/><\/td>\n<td>\u3000<img class=\"wp-image-1876 size-full aligncenter\" src=\"http:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/08\/dimension-02-3.jpg\" alt=\"dimension 02 3\" width=\"422\" height=\"444\" srcset=\"https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/08\/dimension-02-3.jpg 422w, https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/08\/dimension-02-3-285x300.jpg 285w\" sizes=\"(max-width: 422px) 100vw, 422px\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>Wiring:<\/strong><\/p>\n<table width=\"472\">\n<tbody>\n<tr style=\"background-color: #d8d8d8;\">\n<td width=\"218\">Wiring mode<\/td>\n<td width=\"254\">Wiring Diagram<\/td>\n<\/tr>\n<tr>\n<td>Voltage type wiring<\/td>\n<td><img class=\"alignnone wp-image-1881 size-full\" src=\"http:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/08\/wiring-01.jpg\" alt=\"wiring 01\" width=\"311\" height=\"146\" srcset=\"https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/08\/wiring-01.jpg 311w, https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/08\/wiring-01-300x141.jpg 300w\" sizes=\"(max-width: 311px) 100vw, 311px\" \/><\/td>\n<\/tr>\n<tr>\n<td>Current type wiring<\/td>\n<td><img class=\"alignnone wp-image-1882 size-full\" src=\"http:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/08\/wiring-02.jpg\" alt=\"wiring 02\" width=\"455\" height=\"146\" srcset=\"https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/08\/wiring-02.jpg 455w, https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/08\/wiring-02-300x96.jpg 300w\" sizes=\"(max-width: 455px) 100vw, 455px\" \/><\/td>\n<\/tr>\n<tr>\n<td>Digital type wiring<\/td>\n<td><img class=\"alignnone wp-image-1883 size-full\" src=\"http:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/08\/wiring-03.jpg\" alt=\"wiring 03\" width=\"285\" height=\"146\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>Installation attentions:<\/strong><\/p>\n<p><strong>&gt; If conductivity sensor is installed on the pipeline, please pay attention to the following:<\/strong><br \/>\n1. The fluid shall flow through the circular hole of the conductivity sensor, see the following diagram<\/p>\n<p><img class=\"alignnone wp-image-1880\" src=\"http:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/08\/installation-diagram-2.jpg\" alt=\"esquema de instalaci\u00f3n 2\" width=\"286\" height=\"275\" srcset=\"https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/08\/installation-diagram-2.jpg 392w, https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/08\/installation-diagram-2-300x289.jpg 300w\" sizes=\"(max-width: 286px) 100vw, 286px\" \/><br \/>\n2. Leave at least 20mm of space room around the conductivity sensor<\/p>\n<p><strong>\u00a0&gt; If conductivity sensor is installed in the pond or open tank, please pay attention to the following:<\/strong><br \/>\n1. Keep away from the feed inlet.<br \/>\n2. The circular hole of the conductivity sensor shall be inclined to the liquid surface, to avoid the occasional air bubbles staying around the conductivity sensor.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>HG12D-C series conductivity electrode is inductance type electrode, K \u2248 2,\u00a0 applicable to solutions with high conductivity and strong corrosion.\u00a0 It directly output voltage,\u00a0 4-20mA and RS485 digital signal,\u00a0 can be used to match with conductivity transmitter or directly connect to PLC or DCS.<\/p>","protected":false},"featured_media":1877,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_cat":[1600,1755],"product_tag":[],"acf":[],"_links":{"self":[{"href":"https:\/\/www.hginstrument.com\/es\/wp-json\/wp\/v2\/product\/1884"}],"collection":[{"href":"https:\/\/www.hginstrument.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.hginstrument.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hginstrument.com\/es\/wp-json\/wp\/v2\/comments?post=1884"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hginstrument.com\/es\/wp-json\/wp\/v2\/media\/1877"}],"wp:attachment":[{"href":"https:\/\/www.hginstrument.com\/es\/wp-json\/wp\/v2\/media?parent=1884"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.hginstrument.com\/es\/wp-json\/wp\/v2\/product_cat?post=1884"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.hginstrument.com\/es\/wp-json\/wp\/v2\/product_tag?post=1884"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}