{"id":489,"date":"2021-01-15T15:32:49","date_gmt":"2021-01-15T07:32:49","guid":{"rendered":"http:\/\/201230ip92c2.adwebcloud.com\/?post_type=product&p=489"},"modified":"2023-07-05T14:49:39","modified_gmt":"2023-07-05T06:49:39","slug":"hgd-sanitary-electromagnetic-flow-meter","status":"publish","type":"product","link":"https:\/\/www.hginstrument.com\/es\/flow-instrument\/hgd-sanitary-electromagnetic-flow-meter\/","title":{"rendered":"Caudal\u00edmetro electromagn\u00e9tico sanitario HGD"},"content":{"rendered":"
Technical data of HGD Sanitary Electromagnetic Flow Meter<\/h5>\n

\u25cf Applications: Drinking water, fruit juice, milk, Wine, etc.
\n\u25cf Meter size: DN15 – DN150
\n\u25cf Process connection: Tri-clamp
\n\u25cf Tube material: SS304, SS316
\n\u25cf Electrode: SS316L, Hastelloy B, Hastelloy C, Titanium, Tantalum, Pt\/Iridium Alloy, SS with Painting Tungsten Carbide
\n\u25cf Liner: PTFE, FEP, Neoprene, Polyurethane, Hard Rubber, PFA
\n\u25cf Measure accuracy : 1.0%, 0.5%, 0.3%;
\n\u25cf Digital display: instantaneous flow and accumulative flow
\n\u25cf Power supply: 24VDC \/ 220VAC \/ 3.6V battery
\n\u25cf Output: 4-20mA, pulse, frequency (RS485, HART, Profibus-DP optional)<\/p>\n

 <\/p>\n

Wiring Terminal instruction of HGD Sanitary Electromagnetic Flow Meter’s compact converter as follow:<\/strong><\/p>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
Wiring terminal<\/strong><\/td>\nDescripci\u00f3n<\/strong><\/td>\nRemark<\/strong><\/td>\n<\/tr>\n
L 2<\/td>\nConnect 220VAC \/ 24VDC –<\/td>\n<\/td>\n<\/tr>\n
L 1<\/td>\nConnect 220VAC \/ 24VDC +<\/td>\n<\/td>\n<\/tr>\n
COM<\/td>\nCurrent Output Ground for Flow Measurement<\/td>\nUse for wiring of analog Current Output<\/td>\n<\/tr>\n
I +<\/td>\nCurrent Output for Flow Measurement<\/td>\n<\/tr>\n
COM<\/td>\nFrequency \/ Pulse Output Ground<\/td>\nUse for wiring of frequency \/ pulse Output<\/td>\n<\/tr>\n
P+<\/td>\nFrequency \/ Pulse Output for Bi-directional Flow<\/td>\n<\/tr>\n
AH<\/td>\nAlarm Output for Upper Limit<\/td>\nUse for wiring of alarm Output<\/td>\n<\/tr>\n
AL<\/td>\nAlarm Output for Lower Limit<\/td>\n<\/tr>\n
COM<\/td>\nAlarm Output Ground (connect with Current Output Ground or Frequency \/ Pulse Output Ground )<\/td>\n<\/tr>\n
FUSE<\/td>\nFuse for Power Supply<\/td>\n<\/td>\n<\/tr>\n
T +<\/td>\nCommunication terminal (RS485 A+)<\/td>\nUse for wiring of communication<\/td>\n<\/tr>\n
G<\/td>\nRS232 Communication Ground<\/td>\n<\/tr>\n
T –<\/td>\nCommunication terminal (RS485 B-)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n
<\/h5>\n
Wiring Terminal instruction of HGD Sanitary Electromagnetic Flow Meter’s remote converter as follow:<\/h5>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
Wiring terminal<\/strong><\/td>\nDescripci\u00f3n<\/strong><\/td>\nRemark<\/strong><\/td>\n<\/tr>\n
SIG1<\/td>\nSignal l<\/td>\nFor transducer of remote type<\/td>\n<\/tr>\n
SGND<\/td>\nSignal Ground<\/td>\n<\/tr>\n
SIG2<\/td>\nSignal 2<\/td>\n<\/tr>\n
DS1<\/td>\nShielded Exciting\u00a0 1<\/td>\n<\/tr>\n
DS2<\/td>\nShielded Exciting\u00a0 2<\/td>\n<\/tr>\n
EXT +<\/td>\nExciting Current “+”<\/td>\n<\/tr>\n
EXT –<\/td>\nExciting Current “-“<\/td>\n<\/tr>\n
VDIN<\/td>\n24VDC Connect point (for 2-wire current output)<\/td>\nUse for wiring of analog Current Output<\/td>\n<\/tr>\n
IOUT<\/td>\nAnalog Current Output<\/td>\n<\/tr>\n
ICOM<\/td>\nAnalog Current Output Ground<\/td>\n<\/tr>\n
POUT<\/td>\nFlow Frequency (Pulse) Output<\/td>\nUse for wiring of frequency (pulse) Output<\/td>\n<\/tr>\n
PCOM<\/td>\nFrequency (Pulse) Output Ground<\/td>\n<\/tr>\n
ALMH<\/td>\nUpper Limit Alarm Output<\/td>\nUse for wiring of alarm Output<\/td>\n<\/tr>\n
ALML<\/td>\nLower Limit Alarm Output<\/td>\n<\/tr>\n
ACOM<\/td>\nAlarm Output Ground<\/td>\n<\/tr>\n
TRX+<\/td>\nCommunication terminal (RS485 A+)<\/td>\nUse for wiring of communication<\/td>\n<\/tr>\n
TRX-<\/td>\nCommunication terminal (RS485 B-)<\/td>\n<\/tr>\n
TCOM<\/td>\nRS232 Communication Ground<\/td>\n<\/tr>\n
L<\/td>\nConnect 220VAC \/ 24VDC +<\/td>\n<\/td>\n<\/tr>\n
N<\/td>\nConnect 220VAC \/ 24VDC –<\/td>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n
<\/h5>\n
Parameters list of HGD Sanitary Electromagnetic Flow Meter<\/h5>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
Art\u00edculo<\/td>\nParameter words<\/td>\nFunction description<\/td>\nSetting way<\/td>\nGama<\/td>\nPassword Grade<\/td>\n<\/tr>\n
1<\/td>\nLanguage<\/td>\nDisplay language<\/td>\nSelect<\/td>\nChinese \/ English<\/td>\n2<\/td>\n<\/tr>\n
2<\/td>\nComm Addres<\/td>\nInstrument Communication Address<\/td>\nSetting Value<\/td>\n0 ~ 99<\/td>\n2<\/td>\n<\/tr>\n
3<\/td>\nBaud Rate<\/td>\nInstrument Communication Speed<\/td>\nSelect<\/td>\n300 ~ 38400<\/td>\n2<\/td>\n<\/tr>\n
4<\/td>\nSnsr Size<\/td>\nPipe line Size<\/td>\nSelect<\/td>\n3 ~ 3000<\/td>\n2<\/td>\n<\/tr>\n
5<\/td>\nFlow Unit<\/td>\nMeasuring Unit<\/td>\nSelect<\/td>\nL\/h, L\/m, L\/s, m3<\/sup>\/h\u00a0 m3<\/sup>\/min,m3<\/sup>\/s<\/td>\n2<\/td>\n<\/tr>\n
6<\/td>\nFlow Range<\/td>\nMeasure range Setting<\/td>\nSetting Value<\/td>\n0 ~ 99999<\/td>\n2<\/td>\n<\/tr>\n
7<\/td>\nFlow Rspns<\/td>\nMeasure Damping Time<\/td>\nSelect<\/td>\n1 ~ 50<\/td>\n2<\/td>\n<\/tr>\n
8<\/td>\nFlow Direct<\/td>\nMeasuring Direction Selection<\/td>\nSelect<\/td>\nForward \/ Reverse<\/td>\n2<\/td>\n<\/tr>\n
9<\/td>\nFlow Zero<\/td>\nFlow Zero Amendment<\/td>\nSetting Value<\/td>\n0 ~ \u00b19999<\/td>\n2<\/td>\n<\/tr>\n
10<\/td>\nFlow Cutoff<\/td>\nSmall Signal Resection Point<\/td>\nSetting Value<\/td>\n0 ~ 599.99%<\/td>\n2<\/td>\n<\/tr>\n
11<\/td>\nCutoff Ena<\/td>\nResection Point Indication<\/p>\n

Permission<\/td>\n

Select<\/td>\nPermit \uff0fProhibit<\/td>\n2<\/td>\n<\/tr>\n
12<\/td>\nTotal Unit<\/td>\nFlow Totalize Unit<\/td>\nSelect<\/td>\n0.001m3 ~ 1 m3<\/p>\n

0.001 L ~ 1 L<\/td>\n

2<\/td>\n<\/tr>\n
13<\/td>\nSegmaN Ena<\/td>\nReverse Output Permission<\/td>\nSelect<\/td>\nPermit \uff0fProhibit<\/td>\n2<\/td>\n<\/tr>\n
14<\/td>\nAnalog Type<\/td>\nCurrent Output Type<\/td>\nSelect<\/td>\n0 ~ 10 mA \/ 4 ~ 20mA<\/td>\n2<\/td>\n<\/tr>\n
15<\/td>\nPulse Type<\/td>\nPulse Output Mode<\/td>\nSelect<\/td>\nFrequency\uff0fPulse<\/td>\n2<\/td>\n<\/tr>\n
16<\/td>\nPulse Fact<\/td>\nPulse<\/p>\n

Unit equivalent<\/td>\n

Select<\/td>\n0.001m3 ~ 1 m3<\/p>\n

0.001 L ~ 1 L<\/td>\n

2<\/td>\n<\/tr>\n
17<\/td>\nFreque Max<\/td>\nFrequency Output Range<\/td>\nSelect<\/td>\n1 ~ 5999 Hz<\/td>\n2<\/td>\n<\/tr>\n
18<\/td>\nMtsnsr Ena<\/td>\nEmpty pipe Alarm Permission<\/td>\nSelect<\/td>\nPermit\uff0fProhibit<\/td>\n2<\/td>\n<\/tr>\n
19<\/td>\nMtsnsr Trip<\/td>\nEmpty pipe Alarm Threshold<\/td>\nSetting Value<\/td>\n59999%<\/td>\n2<\/td>\n<\/tr>\n
20<\/td>\nAlm Hi Ena<\/td>\nUpper Limit Alarm Permission<\/td>\nSelect<\/td>\nPermit\uff0fProhibit<\/td>\n2<\/td>\n<\/tr>\n
21<\/td>\nAlm Hi Val<\/td>\nUpper Limit Alarm Value<\/td>\nSetting Value<\/td>\n000.0 ~ 599.99%<\/td>\n2<\/td>\n<\/tr>\n
22<\/td>\nAlm Lo Ena<\/td>\nLower Limit Alarm Permission<\/td>\nSelect<\/td>\nPermit\uff0fProhibit<\/td>\n2<\/td>\n<\/tr>\n
23<\/td>\nAlm Lo Val<\/td>\nLower Limit Alarm Value<\/td>\nSetting Value<\/td>\n000.0 ~ 599.99%<\/td>\n2<\/td>\n<\/tr>\n
24<\/td>\nSys Alm Ena<\/td>\nExcitation Alarm Permission<\/td>\nSelect<\/td>\nPermit\uff0fProhibit<\/td>\n2<\/td>\n<\/tr>\n
25<\/td>\nClr Sum Key<\/td>\nTotal Flow Zero Password<\/td>\nSetting Value<\/td>\n0 ~ 99999<\/td>\n3<\/td>\n<\/tr>\n
26<\/td>\nSnsr Code1<\/td>\nSensor Code 1<\/td>\nUser Setting<\/td>\nFactory Year Month (0 ~ 99999)<\/td>\n4<\/td>\n<\/tr>\n
27<\/td>\nSnsr Code2<\/td>\nSensor Code 2<\/td>\nUser Setting<\/td>\nProduct Serial No ( 0 ~ 99999)<\/td>\n4<\/td>\n<\/tr>\n
28<\/td>\nField Type<\/td>\nExciting frequency type<\/td>\nSelect<\/td>\nType 1, 2, 3<\/td>\n4<\/td>\n<\/tr>\n
29<\/td>\nSensor Fact<\/td>\nSensor Factor Value<\/td>\nSetting Value<\/td>\n0.0000 ~ 5.9999<\/td>\n4<\/td>\n<\/tr>\n
30<\/td>\nTotal Point<\/td>\nBatch control volume set<\/td>\nSetting Value<\/td>\n00000\uff5e59999<\/td>\n4<\/td>\n<\/tr>\n
31<\/td>\nLine CRC Ena<\/td>\nFlow amend permission<\/td>\nSelect<\/td>\nPermit\uff0fProhibit<\/td>\n5<\/td>\n<\/tr>\n
32<\/td>\nLineary CRC1<\/td>\nFlow amend point 1<\/td>\nUser Setting<\/td>\nsetting according to the velocity<\/td>\n5<\/td>\n<\/tr>\n
33<\/td>\nLineary Fact 1<\/td>\nFlow amend value 1<\/td>\nUser Setting<\/td>\n0.0000\uff5e1.9999<\/td>\n5<\/td>\n<\/tr>\n
34<\/td>\nLineary CRC2<\/td>\nFlow amend point 2<\/td>\nUser Setting<\/td>\nsetting according to the velocity<\/td>\n5<\/td>\n<\/tr>\n
35<\/td>\nLineary Fact 2<\/td>\nFlow amend value 2<\/td>\nUser Setting<\/td>\n0.0000\uff5e1.9999<\/td>\n5<\/td>\n<\/tr>\n
36<\/td>\nLineary CRC3<\/td>\nFlow amend point 3<\/td>\nUser Setting<\/td>\nsetting according to the velocity<\/td>\n5<\/td>\n<\/tr>\n
37<\/td>\nLineary Fact 3<\/td>\nFlow amend value 3<\/td>\nUser Setting<\/td>\n0.0000\uff5e1.9999<\/td>\n5<\/td>\n<\/tr>\n
38<\/td>\nLineary CRC4<\/td>\nFlow amend point 4<\/td>\nUser Setting<\/td>\nsetting according to the velocity<\/td>\n5<\/td>\n<\/tr>\n
39<\/td>\nLineary Fact4<\/td>\nFlow amend value 4<\/td>\nUser Setting<\/td>\n0.0000\uff5e1.9999<\/td>\n5<\/td>\n<\/tr>\n
40<\/td>\nFwdTotal Lo<\/td>\nForward Total Flow Low Level<\/td>\nRevisable<\/td>\n00000 ~ 99999<\/td>\n5<\/td>\n<\/tr>\n
41<\/td>\nFwdTotal Hi<\/td>\nForward Total Flow High Level<\/td>\nRevisable<\/td>\n0000 ~ 9999<\/td>\n5<\/td>\n<\/tr>\n
42<\/td>\nRevTotal Lo<\/td>\nReverse Total Flow Low Level<\/td>\nRevisable<\/td>\n00000 ~ 99999<\/td>\n5<\/td>\n<\/tr>\n
43<\/td>\nRevTotal Hi<\/td>\nReverse Total Flow High Level<\/td>\nRevisable<\/td>\n0000 ~ 9999<\/td>\n5<\/td>\n<\/tr>\n
44<\/td>\nPlsntLmtEna<\/td>\nPeak Restriction Permission<\/td>\nSelect<\/td>\nPermit\uff0fProhibit<\/td>\n5<\/td>\n<\/tr>\n
45<\/td>\nPlsntLmtVal<\/td>\nPeak Restriction Factor<\/td>\nSelect<\/td>\n0.010 ~ 0.800 m\/s<\/td>\n5<\/td>\n<\/tr>\n
46<\/td>\nPlsnt Delay<\/td>\nPeak Restriction Time<\/td>\nSelect<\/td>\n400 ~ 2500 ms<\/td>\n5<\/td>\n<\/tr>\n
47<\/td>\nPass Word 1<\/td>\nPassword grade 1<\/td>\nUse Revisable<\/td>\n00000 ~ 99999<\/td>\n5<\/td>\n<\/tr>\n
48<\/td>\nPass Word 2<\/td>\nPassword grade 2<\/td>\nUse Revisable<\/td>\n00000 ~ 99999<\/td>\n5<\/td>\n<\/tr>\n
49<\/td>\nPass Word 3<\/td>\nPassword grade 3<\/td>\nUse Revisable<\/td>\n00000 ~ 99999<\/td>\n5<\/td>\n<\/tr>\n
50<\/td>\nPass Word 4<\/td>\nPassword grade 4<\/td>\nUse Revisable<\/td>\n00000 ~ 99999<\/td>\n5<\/td>\n<\/tr>\n
51<\/td>\nAnalog Zero<\/td>\nCurrent Zero Amendment<\/td>\nSetting Value<\/td>\n0.0000 ~ 1.9999<\/td>\n5<\/td>\n<\/tr>\n
52<\/td>\nAnlg Range<\/td>\nCurrent Full Span Amendment<\/td>\nSetting Value<\/td>\n0.0000 ~ 3.9999<\/td>\n5<\/td>\n<\/tr>\n
53<\/td>\nMeter Fact<\/td>\nCalibration Factor<\/td>\nSetting Value<\/td>\n0.0000 ~ 5.9999<\/td>\n5<\/td>\n<\/tr>\n
54<\/td>\nMeterCode 1<\/td>\nInstrument Code 1<\/td>\nFactory Setting<\/td>\nFactory Year Month (0 ~ 99999)<\/td>\n6<\/td>\n<\/tr>\n
55<\/td>\nMeterCode 2<\/td>\nInstrument Code 2<\/td>\nFactory Setting<\/td>\nProduct Serial No. (0~99999)<\/td>\n6<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n
Workshop Assembly line<\/h5>\n
\u00a0 \u00a0\"workshop<\/h5>\n
<\/h5>\n

 <\/p>\n

Workshop Calibration line<\/h5>\n

\"\"<\/p>\n

 <\/p>\n

Warehouse<\/h5>\n

\"warehouse\"<\/p>\n

 <\/p>","protected":false},"excerpt":{"rendered":"

Product name: Caudal\u00edmetro electromagn\u00e9tico sanitario HGD<\/span><\/a>
\nThe operation temperature of HGD Sanitary Electromagnetic Flow Meter usually not more than 120\u2103, fluid’s conductivity not less than 5\u03bcS\/cm.
\nHGD Sanitary Electromagnetic Flow Meter is applicable for the industry of high health level requirement, such as pharmaceutical, food industry etc.
\nHot Tags:<\/strong>
Acerca del Grupo Suyi<\/span><\/a>\uff0cInstrumento de flujo<\/a><\/span>\uff0cTransmisor de nivel<\/a><\/span>\uff0ccaudal\u00edmetro de agua<\/a><\/span><\/p>","protected":false},"featured_media":1446,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_cat":[75,220],"product_tag":[],"acf":[],"_links":{"self":[{"href":"https:\/\/www.hginstrument.com\/es\/wp-json\/wp\/v2\/product\/489"}],"collection":[{"href":"https:\/\/www.hginstrument.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.hginstrument.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hginstrument.com\/es\/wp-json\/wp\/v2\/comments?post=489"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hginstrument.com\/es\/wp-json\/wp\/v2\/media\/1446"}],"wp:attachment":[{"href":"https:\/\/www.hginstrument.com\/es\/wp-json\/wp\/v2\/media?parent=489"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.hginstrument.com\/es\/wp-json\/wp\/v2\/product_cat?post=489"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.hginstrument.com\/es\/wp-json\/wp\/v2\/product_tag?post=489"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}