{"id":706,"date":"2021-02-26T13:58:35","date_gmt":"2021-02-26T05:58:35","guid":{"rendered":"http:\/\/201230ip92c2.adwebcloud.com\/?post_type=product&p=706"},"modified":"2023-08-16T11:36:09","modified_gmt":"2023-08-16T03:36:09","slug":"liquid-turbine-flow-meter","status":"publish","type":"product","link":"https:\/\/www.hginstrument.com\/es\/flow-instrument\/liquid-turbine-flow-meter\/","title":{"rendered":"Caudal\u00edmetro de turbina de l\u00edquido"},"content":{"rendered":"
SPECIFICATIONS<\/strong><\/h5>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
Repeatability<\/td>\n\u00b10.2%<\/td>\n<\/tr>\n
Precisi\u00f3n<\/td>\n\u00b11% of reading; \u00a0\u00b10.5% of reading ( Optional )<\/td>\n<\/tr>\n
Body material<\/td>\nSS304, SS316 (optional)<\/td>\n<\/tr>\n
Bearings and Shaft<\/td>\nTungsten Carbide<\/td>\n<\/tr>\n
Vane<\/td>\nStainless Iron, SS304\/SS316\/duplex steel (optional)<\/td>\n<\/tr>\n
Output Signal<\/td>\nSensor type: Pulse signal (Low Level: \u22640.8V; High Level: \u22658V)
\nTransmitter type: 4 to 20 mA DC current<\/td>\n<\/tr>\n
Signal Transmission<\/td>\nDistance \u22641000 m<\/td>\n<\/tr>\n
Electrical Connection<\/td>\nISO M20\u00d71.5 Female<\/td>\n<\/tr>\n
Explosion Proof<\/td>\nExdIIBT6\/ExiaIIBT4 ( Optional )<\/td>\n<\/tr>\n
Whether-proof<\/td>\nIP65<\/td>\n<\/tr>\n
Power Supply<\/td>\nSensor type: +12V DC (Optional: +24V DC)
\nTransmitter type: +24V DC, 3.6V Lithium Battery ( Optional )<\/td>\n<\/tr>\n
Process Temperature<\/td>\n-20\u00b0C to +110\u00b0C<\/td>\n<\/tr>\n
Pressure rating<\/td>\nAccording to process pressure<\/td>\n<\/tr>\n
Ambient Temperature<\/td>\n-10\u00b0C to +55\u00b0C<\/td>\n<\/tr>\n
Ambient Pressure<\/td>\n86 to 106 KPa<\/td>\n<\/tr>\n
Relative Humidity<\/td>\n5% to 90% RH<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n
<\/h5>\n

 <\/p>\n

Measurable range<\/strong><\/h5>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
DN<\/strong><\/td>\nStandard flow Range (m3\/h)<\/strong><\/td>\nExtended flow range (m3\/h)<\/strong><\/td>\nConexi\u00f3n a proceso<\/strong><\/td>\n<\/tr>\n
4<\/td>\n0.04 \u2013 0.25<\/td>\n0.04 \u2013 0.4<\/td>\nThread<\/td>\n<\/tr>\n
6<\/td>\n0.1 \u2013 0.6<\/td>\n0.06 \u2013 0.6<\/td>\nThread<\/td>\n<\/tr>\n
10<\/td>\n0.2 \u2013 1.2<\/td>\n0.15 \u2013 1.5<\/td>\nThread<\/td>\n<\/tr>\n
15<\/td>\n0.6 \u2013 6<\/td>\n0.4 \u2013 8<\/td>\nThread \/ Flange<\/td>\n<\/tr>\n
20<\/td>\n0.8 \u2013 8<\/td>\n045 \u2013 9<\/td>\nThread \/ Flange<\/td>\n<\/tr>\n
25<\/td>\n1 – 10<\/td>\n0.5 – 10<\/td>\nThread \/ Flange<\/td>\n<\/tr>\n
32<\/td>\n1.5 – 15<\/td>\n0.8 – 15<\/td>\nThread \/ Flange<\/td>\n<\/tr>\n
40<\/td>\n2 – 20<\/td>\n1 \u2013 30<\/td>\nThread \/ Flange<\/td>\n<\/tr>\n
50<\/td>\n4 – 40<\/td>\n2 – 40<\/td>\nFlange<\/td>\n<\/tr>\n
65<\/td>\n7 – 70<\/td>\n4 – 70<\/td>\nFlange<\/td>\n<\/tr>\n
80<\/td>\n10 – 100<\/td>\n5 – 100<\/td>\nFlange<\/td>\n<\/tr>\n
100<\/td>\n20 – 200<\/td>\n10 – 200<\/td>\nFlange<\/td>\n<\/tr>\n
125<\/td>\n25 – 250<\/td>\n13 – 250<\/td>\nFlange<\/td>\n<\/tr>\n
150<\/td>\n30 – 300<\/td>\n15 – 300<\/td>\nFlange<\/td>\n<\/tr>\n
200<\/td>\n80 – 800<\/td>\n40 – 800<\/td>\nFlange<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

 <\/p>\n

Instrument Classification<\/strong><\/h5>\n\n\n\n\n\n\n
Sensor type<\/td>\nThread connection
\n\"lwgy<\/td>\n
Model: LTB – <\/strong>\u25a1<\/strong>N<\/strong><\/p>\n

12 ~ 24V DC power supply, 3 wire pulse output, high level more than 8V, low level less than 0.8V; signal transmission distance less than 1000 m.<\/td>\n<\/tr>\n

Flange connection
\n\"lwgy<\/td>\n<\/tr>\n
Tri-clamp connection
\n\"lwgy<\/td>\n<\/tr>\n
Transmitter
\ntype<\/td>\n
\"ltb<\/td>\nModel: LTB – <\/strong>\u25a1<\/strong>A \/ B \/ C \/ C1 \/ C2<\/strong>
\n\u00a0<\/strong>
\nPower supply option:<\/strong> 24VDC, 220VAC, 3.6V Lithium Battery
\nOutput signal:<\/strong> 4-20 mA \/ pulse for external powered
\nNo output for Battery powered
\nCommunication option:<\/strong> RS485, HART<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

 <\/p>\n

Flow sensor construction<\/strong><\/h5>\n

\"sensor<\/p>\n

 <\/p>\n

 <\/p>","protected":false},"excerpt":{"rendered":"

LTB series turbine flow meter have the features: high accuracy, good repeatability, convenient installation\/maintenance, simple structure etc.
\nLiquid flows through the meter tube which drive the internal rotor rotating to generate an electrical signal in the pickup coil, this signal is converted into engineering units (liters, cubic meters, gallons etc.) on local display. Optional accessory modules can be used to output the signal to other equipment.
\nHot Tags: \uff1aflow instrument manufacturer<\/span><\/a>\uff0cMore flow instrument products<\/span><\/a><\/p>","protected":false},"featured_media":1359,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_cat":[75,342],"product_tag":[],"acf":[],"_links":{"self":[{"href":"https:\/\/www.hginstrument.com\/es\/wp-json\/wp\/v2\/product\/706"}],"collection":[{"href":"https:\/\/www.hginstrument.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.hginstrument.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hginstrument.com\/es\/wp-json\/wp\/v2\/comments?post=706"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hginstrument.com\/es\/wp-json\/wp\/v2\/media\/1359"}],"wp:attachment":[{"href":"https:\/\/www.hginstrument.com\/es\/wp-json\/wp\/v2\/media?parent=706"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.hginstrument.com\/es\/wp-json\/wp\/v2\/product_cat?post=706"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.hginstrument.com\/es\/wp-json\/wp\/v2\/product_tag?post=706"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}