{"id":956,"date":"2021-06-04T10:25:01","date_gmt":"2021-06-04T02:25:01","guid":{"rendered":"http:\/\/201230ip92c2.adwebcloud.com\/?post_type=product&p=956"},"modified":"2021-10-12T13:50:59","modified_gmt":"2021-10-12T05:50:59","slug":"portable-doppler-ultrasonic-flow-meter-clamp-on-flow-sensor","status":"publish","type":"product","link":"https:\/\/www.hginstrument.com\/es\/flow-instrument\/portable-doppler-ultrasonic-flow-meter-clamp-on-flow-sensor\/","title":{"rendered":"Caudal\u00edmetro ultras\u00f3nico Doppler port\u00e1til ( Sensor de caudal con pinza )"},"content":{"rendered":"
Features\uff1a<\/strong> <\/p>\n Applications\uff1a<\/strong> <\/p>\n Technical data of Transmitter:<\/strong><\/p>\n <\/p>\n Technical data of\u00a0 Transducer:<\/strong><\/p>\n <\/p>\n <\/p>","protected":false},"excerpt":{"rendered":" Principle: use Doppler frequency shift to measure the flow velocity, it <\/span>is suitable for measuring the fluid which contains solid particles or bubbles, not suitable for measuring pure water. <\/span>The application scope includes: natural river course, artificial river course, farmland channel, city sewer, enterprise sewage outlet, sewage treatment plant and so on.<\/span><\/p>","protected":false},"featured_media":1276,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_cat":[75,1040],"product_tag":[],"acf":[],"_links":{"self":[{"href":"https:\/\/www.hginstrument.com\/es\/wp-json\/wp\/v2\/product\/956"}],"collection":[{"href":"https:\/\/www.hginstrument.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.hginstrument.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hginstrument.com\/es\/wp-json\/wp\/v2\/comments?post=956"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hginstrument.com\/es\/wp-json\/wp\/v2\/media\/1276"}],"wp:attachment":[{"href":"https:\/\/www.hginstrument.com\/es\/wp-json\/wp\/v2\/media?parent=956"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.hginstrument.com\/es\/wp-json\/wp\/v2\/product_cat?post=956"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.hginstrument.com\/es\/wp-json\/wp\/v2\/product_tag?post=956"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}
\n\u25cf Suitable for pipe sizes ranging from 40 to 4000mm
\n\u25cf Clamp-on sensor, pipe must be fully filled with liquid
\n\u25cf The fluid must include a certain amount of air bubbles or suspended solid particles
\n\u25cf Excellent low flow rate measurement ability, low to 0.05m\/s
\n\u25cf A wide range of flow measurement, high flow rate can reach 12m\/s
\n\u25cf High-temperature transducer is suitable for liquids with temperature from -35\u2103 ~ 200\u2103
\n\u25cf No need to shut down the pipe flow when installing the transducers
\n\u25cf User-friendly configuration
\n\u25cf 4-20mA, OCT outputs
\n\u25cf Accuracy: 2.0% F.S.
\n\u25cf Rechargeable battery, working up to 50 hours<\/p>\n
\n\u25cf Raw sewage
\n\u25cf Activated sludge
\n\u25cf Ground water
\n\u25cf Pulp and paper slurry
\n\u25cf Chemical slurry
\n\u25cf Drainage
\n\u25cf Mining re-circulation<\/p>\n\n\n
\n Measurement principle<\/td>\n Doppler ultrasonic<\/td>\n<\/tr>\n \n Resolution<\/td>\n 0.25 mm\/s<\/td>\n<\/tr>\n \n Repeatability<\/td>\n 0.2% of reading<\/td>\n<\/tr>\n \n Precisi\u00f3n<\/td>\n 0.5% — 2.0% F.S.<\/td>\n<\/tr>\n \n Response time<\/td>\n 2-60s for optional<\/td>\n<\/tr>\n \n Flow Velocity<\/td>\n 0.05- 12 m\/s<\/td>\n<\/tr>\n \n Liquid Types Supported<\/td>\n Liquids containing 100ppm of reflectors and at least 20% of the reflectors are larger than 100 micron.<\/td>\n<\/tr>\n \n Power Supply<\/td>\n 85-265V AC<\/td>\n<\/tr>\n \n Enclosure type<\/td>\n Portable<\/td>\n<\/tr>\n \n Degree of protection<\/td>\n IP65<\/td>\n<\/tr>\n \n Operating temperature<\/td>\n \u00a0-20\u2103 to +60\u2103<\/td>\n<\/tr>\n \n Material de la carcasa<\/td>\n ABS<\/td>\n<\/tr>\n \n Measurement Channels<\/td>\n 1<\/td>\n<\/tr>\n \n Mostrar<\/td>\n 2 line \u00d7 8 characters LCD, 8-digit rate or 8-digit total (resettable)<\/td>\n<\/tr>\n \n Units<\/td>\n User Configured (English and Metric)<\/td>\n<\/tr>\n \n Rate<\/td>\n Rate and Velocity Display<\/td>\n<\/tr>\n \n Totalized<\/td>\n gallons, ft\u00b3, barrels, lbs, liters, m\u00b3,kg<\/td>\n<\/tr>\n \n Comunicaci\u00f3n<\/td>\n 4-20mA,OCT output<\/td>\n<\/tr>\n \n keypad<\/td>\n 6 pcs buttons<\/td>\n<\/tr>\n \n Talla<\/td>\n Transmitter: 270 x 125 x 175 mm<\/td>\n<\/tr>\n \n Weight<\/td>\n 3 kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n \n\n
\n Transducers Type<\/td>\n Clamp-on<\/td>\n<\/tr>\n \n Degree of protection<\/td>\n IP65. IP67 or IP68<\/td>\n<\/tr>\n \n Suited Liquid Temperature<\/td>\n Std. Temp.: -35\u2103~85\u2103 for short periods up to 120\u2103<\/td>\n<\/tr>\n \n High Temp.: -35\u2103~200\u2103 for short periods up to 250\u2103<\/td>\n<\/tr>\n \n Pipe size<\/td>\n 40-4000 mm<\/td>\n<\/tr>\n \n Transducer Size<\/td>\n 60(h)*34(w)*33(d)mm<\/td>\n<\/tr>\n \n Material of transducer<\/td>\n Aluminum for standard temp. sensor, peek for high temp. sensor<\/td>\n<\/tr>\n \n Cable Length<\/td>\n Std: 5m<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n