{"id":1712,"date":"2021-08-13T09:26:44","date_gmt":"2021-08-13T01:26:44","guid":{"rendered":"http:\/\/201230ip92c2.adwebcloud.com\/?post_type=product&p=1712"},"modified":"2021-10-11T15:55:13","modified_gmt":"2021-10-11T07:55:13","slug":"thermocouple","status":"publish","type":"product","link":"https:\/\/www.hginstrument.com\/fr\/temperature-instrument\/thermocouple\/","title":{"rendered":"Thermocouple"},"content":{"rendered":"
Type de thermocouple :<\/strong><\/p>\n <\/p>\n Structure de la sonde :<\/strong><\/p>\n <\/p>\n Informations sur la commande :<\/strong> <\/p>\n <\/p>\n <\/p>","protected":false},"excerpt":{"rendered":" Le thermocouple est compos\u00e9 d'un \u00e9l\u00e9ment thermique, d'un mat\u00e9riau isolant (c\u00e9ramique ou MgO) et d'une gaine de protection.<\/p>","protected":false},"featured_media":1689,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_cat":[1540,1542],"product_tag":[],"acf":[],"_links":{"self":[{"href":"https:\/\/www.hginstrument.com\/fr\/wp-json\/wp\/v2\/product\/1712"}],"collection":[{"href":"https:\/\/www.hginstrument.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.hginstrument.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hginstrument.com\/fr\/wp-json\/wp\/v2\/comments?post=1712"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hginstrument.com\/fr\/wp-json\/wp\/v2\/media\/1689"}],"wp:attachment":[{"href":"https:\/\/www.hginstrument.com\/fr\/wp-json\/wp\/v2\/media?parent=1712"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.hginstrument.com\/fr\/wp-json\/wp\/v2\/product_cat?post=1712"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.hginstrument.com\/fr\/wp-json\/wp\/v2\/product_tag?post=1712"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}\n\n
\n Code de type<\/td>\n Mat\u00e9riau du fil thermo\u00e9lectrique<\/td>\n Plage de mesure<\/td>\n Valeur de tol\u00e9rance<\/td>\n<\/tr>\n \n B<\/td>\n PtRh30-PtRh<\/td>\n 600 ~ 1700 \u2103<\/td>\n \u00b11,5 \u2103 ou \u00b10,25% t<\/td>\n<\/tr>\n \n S<\/td>\n PtRh10-Pt<\/td>\n 0 ~ 1600 \u2103<\/td>\n \u00b11,5 \u2103 ou \u00b10,25% t<\/td>\n<\/tr>\n \n K<\/td>\n Nicr-NiSi<\/td>\n 0 ~ 1200 \u2103<\/td>\n \u00b12,5 \u2103 ou \u00b10,75% t<\/td>\n<\/tr>\n \n E<\/td>\n Nicr-CuNi<\/td>\n 0 ~ 800 \u2103<\/td>\n \u00b12,5 \u2103 ou \u00b10,75% t<\/td>\n<\/tr>\n \n T<\/td>\n Cu-cuNi<\/td>\n -40 ~ 350 \u2103<\/td>\n \u00b11 \u2103 ou \u00b10,75% t<\/td>\n<\/tr>\n \n J<\/td>\n Te-CuNi<\/td>\n 0 ~ 800 \u2103<\/td>\n \u00b12,5 \u2103 ou \u00b10,75% t<\/td>\n<\/tr>\n \n N<\/td>\n NiCrSi-NiSi<\/td>\n 0 ~ 1200 \u2103<\/td>\n \u00b12,5 \u2103 ou \u00b10,75% t<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n
<\/p>\n
\n\u25cf Milieu mesur\u00e9 : ?
\n\u25cf Plage de temp\u00e9rature: ?
\n\u25cf Type de capteur : ?
\n\u25cf Diam\u00e8tre du capteur : ?
\n\u25cf Connexion au processus: ?
\n\u25cf Longueur d'insertion et longueur totale: ?
\n\u25cf Mat\u00e9riau : ?<\/p>\n