{"id":3354,"date":"2023-05-25T16:28:40","date_gmt":"2023-05-25T08:28:40","guid":{"rendered":"https:\/\/www.hginstrument.com\/?post_type=product&p=3354"},"modified":"2023-11-14T09:39:47","modified_gmt":"2023-11-14T01:39:47","slug":"hgrs-thermal-mass-flow-meter","status":"publish","type":"product","link":"https:\/\/www.hginstrument.com\/fr\/flow-instrument\/hgrs-thermal-mass-flow-meter\/","title":{"rendered":"HGRS Thermal Mass Flow Meter"},"content":{"rendered":"
<\/p>\n
1)\u00a0 The instrument should be installed away from the elbow, obstructions, reducers, valves, in order to ensure a steady flow field. Requirement to upstream straight pipe length and downstream straight pipe length as the following diagram shown( D is pipeline diameter):<\/p>\n
<\/p>\n
2)\u00a0<\/strong> When installing for HGRS Thermal Gas Mass Flow Meter, the short RTD sensor (RTD1) should face the direction of airflow, see the following diagram:<\/p>\n 3)\u00a0<\/strong> HGRS Thermal Mass Flow Meter’s sensor is actually a gas flow velocity sensor. Gas flows in pipeline, flow velocity of each point in the pipeline is different, generally the flow velocity at pipe’s wall is very slow but very fast at pipe’s center. So flow velocity at the detected point should be the average velocity throughout the pipe, the accuracy of average flow velocity point is directly related to accuracy of measurement. In order to get an optimal insertion length to make measurement more accurate, please supply detailed process condition before ordering.<\/p>\n <\/p>\n Main display interface of HGRS Thermal Mass Flow Meter<\/strong><\/p>\n When the instrument is powered on, it will automatically do self-test, if self-test is ok, screen will display “Thermal Mass Flow meter” , then appears the main display interface as follow:<\/strong><\/p>\n <\/p>\n 1:<\/strong> \u00a0\u201cAL1\u201d means channel1 alarming, \u201cAL2\u201d means channel2 alarming, user can select one or two variables to set limit alarm, the variables that can be set to alarm are instant flow rate, flow velocity, temperature.<\/p>\n 2:<\/strong> \u00a0When the measured value exceeds the set value range, this area will display “OV”, which is the identifier of variable value overflow.<\/p>\n 3:<\/strong> When the total flow exceeds 10000000, this area will display \u201d1K\u201d, which means the actual total flow equal to total flow display value multiply by 1000.<\/p>\n 4:<\/strong> Communication status indication, the first 3 digit is instrument’s address code;<\/p>\n The fourth digit is check digit, 0: none parity, 1: odd parity, 2: even parity;<\/p>\n The fifth digit is baud rate code, 0: 1200 bps, 1: 2400 bps, 2: 4800 bps, 3: 9600 bps.<\/p>\n 5:<\/strong> Instantaneous flow rate, maximum display is 9999999<\/p>\n 6:<\/strong> Total flow, maximum display of integer area is 8 digits, decimal area is 4 digits.<\/p>\n 7: <\/strong>The current flow velocity (unit: Nm\/s)<\/p>\n 8: <\/strong>This area display flow rate percentage or temperature ( it depends on the configuration of the instrument )<\/p>\n FAQ:<\/strong><\/p>\n 1. What is Thermal Mass Flow Meter? 2. What is the working principle of Thermal Mass Flow Meter? 3. What fluids is the Thermal Mass Flow Meter suitable for? 4. What is the difference between Thermal Mass Flow Meter and other flow meters? 5. What are the advantages of Thermal Mass Flow Meter? 6. What parameters does Thermal Mass Flow Meter require for measurement? 7. What is the measurement accuracy of Thermal Mass Flow Meter? 8. How to choose a suitable Thermal Mass Flow Meter? 9. What are the requirements for the installation location of Thermal Mass Flow Meter? 10. How to maintain and maintain the Thermal Mass Flow Meter? Before ordering HGRS Thermal Mass Flow Meter, need to confirm the following process information:<\/strong><\/p>\n
<\/p>\n
<\/p>\n
\n<\/strong>The Thermal Mass Flow Meter is a meter that measures the flow of a gas or liquid by measuring the heat it transfers within a pipe.<\/p>\n
\n<\/strong>The Thermal Mass Flow Meter works by measuring the heat absorbed by a fluid as it passes through a pipe to calculate flow. When the fluid passes through the pipe, heat will be transferred to the pipe wall. The Thermal Mass Flow Meter will measure the temperature change of the pipe wall and calculate the flow rate of the fluid based on the law of heat conduction.<\/p>\n
\n<\/strong>Thermal Mass Flow Meter is suitable for the measurement of non-corrosive fluids such as gases and liquids.<\/p>\n
\n<\/strong>Compared with other flow meters, the Thermal Mass Flow Meter has a wider measurement range, can measure both low and high flow, and can be suitable for many different fluids. In addition, the Thermal Mass Flow Meter has high accuracy and stability, and has automatic temperature and pressure compensation functions.<\/p>\n
\n<\/strong>The Thermal Mass Flow Meter has the advantages of fast response, high accuracy, strong reliability, easy installation and maintenance, and is suitable for a variety of industrial and laboratory applications.<\/p>\n
\n<\/strong>The parameters that the Thermal Mass Flow Meter needs to measure include fluid temperature, pressure and density.<\/p>\n
\n<\/strong>The measurement accuracy of Thermal Mass Flow Meter depends on the specific instrument model and measurement range used, and generally can reach an accuracy of about 1%.<\/p>\n
\n<\/strong>When choosing a suitable Thermal Mass Flow Meter, you need to consider factors such as flow range, fluid type, usage environment, accuracy requirements, and installation methods. You can consult relevant professionals for help based on specific needs.<\/p>\n
\n<\/strong>The installation location requirements of Thermal Mass Flow Meter usually include: installation on horizontal pipes, avoiding the entry of large pieces of fluid or particles, stable pipe diameter, and avoiding direct sunlight, etc.<\/p>\n
\n<\/strong>Care and maintenance of Thermal Mass Flow Meter requires regular calibration, checking whether the sensor and circuit are damaged, keeping it clean and free from external interference, etc. Please refer to the product manual for details.<\/p>\n