Wall Mounted Doppler Ultrasonic Flow Meter ( Clamp-on flow sensor )
wall mounted Doppler ultrasonic flowmeter Principle: use Doppler frequency shift to measure the flow velocity, it is suitable for measuring the fluid which contains solid particles or bubbles, not suitable for measuring pure water. The application scope includes: natural river course, artificial river course, farmland channel, city sewer, enterprise sewage outlet, sewage treatment plant and so on.
Tag caldi: Strumento di flusso,Trasmettitore di livello,misuratore di portata dell'acqua
Descrizione del prodotto
Features:
● Suitable for pipe sizes ranging from 40 to 4000mm
● Clamp-on sensor, pipe must be fully filled with liquid
● The fluid must include a certain amount of air bubbles or suspended solid particles
● Excellent low flow rate measurement ability, low to 0.05 m/s
● A wide range of flow measurement, high flow rate can reach 12 m/s
● High-temperature transducer is suitable for liquids with temperature from -35℃ ~ 200℃
● No need to shut down the pipe flow when installing the transducers
● User-friendly configuration
● 4-20mA, Relay and OCT outputs
● Accuracy: 2.0% F.S.
Applications:
● Raw sewage
● Activated sludge
● Ground water
● Pulp and paper slurry
● Chemical slurry
● Drainage
● Mining re-circulation
Technical data of Transmitter:
| Measurement principle | Doppler ultrasonic |
| Resolution | 0.25 mm/s |
| Ripetibilità | 0.2% of reading |
| Precisione | 0.5% — 2.0% F.S. |
| Response time | 2-60s for optional |
| Flow Velocity Range | 0.05- 12 m/s |
| Liquid Types Supported | Liquids containing 100 ppm of reflectors and at least 20% of the reflectors are larger than 100 micron. |
| Alimentazione | 85-265V AC, 24V DC/500mA |
| Enclosure type | Wall-mounted |
| Degree of protection | IP66 |
| Operating temperature | -20℃ to +60℃ |
| Housing material | Fiberglass |
| Measurement Channels | 1 |
| Display | 2 line × 8 characters LCD, 8-digit rate or 8-digit total (resettable) |
| Units | User Configured (English and Metric) |
| Rate | Rate and Velocity Display |
| Totalizer | gallons, ft³, barrels, lbs, liters, m³,kg |
| Comunicazione | 4-20mA, Relay and OCT output |
| keypad | 4 buttons |
| Dimensione | 244(h)*196(w)*114(d)mm |
| Peso | 2.4kg |
Technical data of Transducer:
| Transducers Type | Clamp-on |
| Degree of protection | IP65. IP67 or IP68 |
| Suited Liquid Temperature | Standard. Temp.: -35℃~85℃ for short periods up to 120℃ |
| High Temp.: -35℃~200℃ for short periods up to 250℃ | |
| Pipe diameter range | 40-4000 mm |
| Transducer Size | 60(h)*34(w)*32(d)mm |
| Material of transducer | Aluminum for standard temp. sensor,and peek for high temp. sensor |
| Cable Length | Standard configure: 2 * 5m |
Prodotti correlati
-
Strumento di flusso
Misuratore di portata a ultrasuoni a parete HGLS-2000B
Voto 0 su 5Per saperne di più
FAQ
Arisposta : Inviate la vostra domanda o richiesta al nostro indirizzo e-mail: sales@hginstrument.com, inoltreremo le domande all'ingegnere di riferimento.
Arisposta : Per favore comunicare con le vendite la procedura di restituzione prima di restituire il prodotto.
Arisposta : I tempi di consegna dipendono dalla quantità ordinata e dalle specifiche del prodotto. Se le specifiche del prodotto sono convenzionale (non speciale), I tempi di consegna sono di 5 o 7 giorni lavorativi per quantità d'ordine ≤ 10 pezzi; I tempi di consegna sono di 2 o 3 settimane lavorative per quantità d'ordine 15 ~ 30 pezzi.
Arisposta Per corriere, via mare o per via aerea
Arisposta : Sì, in genere la garanzia è di un anno.
Arisposta : Dal 2015 al 2021, il fatturato medio annuo è di 350 milioni di RMB (circa 54,7 milioni di USD).