{"id":3145,"date":"2022-05-10T10:16:20","date_gmt":"2022-05-10T02:16:20","guid":{"rendered":"https:\/\/www.hginstrument.com\/?p=3145"},"modified":"2022-05-10T10:19:55","modified_gmt":"2022-05-10T02:19:55","slug":"common-faults-and-treatment-of-vortex-flow-meter","status":"publish","type":"post","link":"https:\/\/www.hginstrument.com\/it\/common-faults-and-treatment-of-vortex-flow-meter\/","title":{"rendered":"Guasti comuni e trattamento del misuratore di portata a vortice"},"content":{"rendered":"<table width=\"1309\">\n<tbody>\n<tr style=\"background-color: #d8d8d8;\">\n<td style=\"text-align: center;\" colspan=\"2\" width=\"498\">Fenomeno di guasto<\/td>\n<td style=\"text-align: center;\" width=\"405\">Motivo<\/td>\n<td style=\"text-align: center;\" width=\"406\">Misure di trattamento<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: middle;\" rowspan=\"2\" width=\"250\">The luid is flowing in the pipeline, but the flow meter has no output<\/td>\n<td style=\"vertical-align: middle;\" width=\"248\">Flow meter has no display no output<\/td>\n<td width=\"405\">1.The power supply is faulty.<br \/>\n2.The power supply is not connected.<br \/>\n3.The connection cable is disconnected or incorrectly connected.<\/td>\n<td width=\"406\">1.Replace the power supply with a new one.<br \/>\n2.Switch on the power.<br \/>\n3.Rewire and check the cables.<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: middle;\" width=\"248\">Flow meter has display but no output<\/td>\n<td width=\"405\">1. The flow rate is too low, is not in the measurement range.<br \/>\n2. Some stage of amplifier circuit is faulty.<br \/>\n3. The probe body is damaged.<br \/>\n4. Pipes are blocked or sensors are jammed.<\/td>\n<td width=\"406\">1. Increase the flow rate or reselect the flow meter.<br \/>\n2. Replace the main PCB<br \/>\n3. Change the probe<br \/>\n4. Reinstall the flow meter.<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: middle;\" rowspan=\"2\" width=\"250\">No flow rate but has output after power on<\/td>\n<td style=\"vertical-align: middle;\" width=\"248\">Output signal is stable<\/td>\n<td width=\"405\">1. The output frequency is 50 Hz, power frequency interference.<br \/>\n2. The amplifier plate is damaged and produces self-excitation.<\/td>\n<td width=\"406\">1. Choose shielded cable and reconnect it as required.<br \/>\n2. Replace the amplifier.<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: middle;\" width=\"248\">The output signal is variable<\/td>\n<td width=\"405\">1. There is strong electric equipment or high frequency interference near the flowmeter.<br \/>\n2. There was a strong shock in the pipe.<br \/>\n3. The magnification or trigger sensitivity of the amplifier plate is too high.<br \/>\n4. Pipeline valve is not completely closed, there is leakage flow.<\/td>\n<td width=\"406\">1. Select a new installation site.<br \/>\n2. Reinforce the pipeline at the position where the flowmeter is installed.<br \/>\n3. Counterclockwise reduce magnification (GB) or sensitivity (SB)<br \/>\n4. Check the valve<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: middle;\" rowspan=\"2\" width=\"250\">Output flow signal is not stable<\/td>\n<td style=\"vertical-align: middle;\" width=\"248\">Reasons of model selection, installation and pipeline<\/td>\n<td width=\"405\">1. There is strong electrical interference signal, instrument is not grounded, flow signal is overlayed with interference signal.<br \/>\n2. Straight pipe length is not enough or pipeline inner diameter inconsistent with instrument inner diameter.<br \/>\n3. The impact of pipe vibration.<br \/>\n4. Flowmeter measure tube&#8217;s axes is not at the pipeline&#8217;s axes.<br \/>\n5. The pipeline is not fully filled with fluid.<br \/>\n6. The flow rate is below the lower limit or exceeds the upper limit.<br \/>\n7. There is cavitation in the fluid.<\/td>\n<td width=\"406\">1. Reconnect the ground.<br \/>\n2. Select the suitable installation position.<br \/>\n3. Reinforce the pipeline to reduce vibration.<br \/>\n4. Reinstall the flow meter.<br \/>\n5. Check flowing condition of the fluid and instrument installation position.<br \/>\n6. Increase or decrease the flow rate or adjust the filter coefficient of the amplifier board.<br \/>\n7. Install valve at the downstream of instrument to increase back pressure.<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: middle;\" width=\"248\">Reason of the instrument itself<\/td>\n<td width=\"405\">1. Parameter setting is error.<br \/>\n2. The mainboard is damaged.<\/td>\n<td width=\"406\">1. Re-setup the instrument&#8217;s parameters.<br \/>\n2. Replace the mainboard.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>Guasti comuni e trattamento del misuratore di portata a vortice<\/p>","protected":false},"author":1,"featured_media":2768,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[2130],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/www.hginstrument.com\/it\/wp-json\/wp\/v2\/posts\/3145"}],"collection":[{"href":"https:\/\/www.hginstrument.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.hginstrument.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.hginstrument.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hginstrument.com\/it\/wp-json\/wp\/v2\/comments?post=3145"}],"version-history":[{"count":0,"href":"https:\/\/www.hginstrument.com\/it\/wp-json\/wp\/v2\/posts\/3145\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hginstrument.com\/it\/wp-json\/wp\/v2\/media\/2768"}],"wp:attachment":[{"href":"https:\/\/www.hginstrument.com\/it\/wp-json\/wp\/v2\/media?parent=3145"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.hginstrument.com\/it\/wp-json\/wp\/v2\/categories?post=3145"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.hginstrument.com\/it\/wp-json\/wp\/v2\/tags?post=3145"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}