{"id":3350,"date":"2023-05-25T15:59:31","date_gmt":"2023-05-25T07:59:31","guid":{"rendered":"https:\/\/www.hginstrument.com\/?p=3350"},"modified":"2023-05-25T16:59:36","modified_gmt":"2023-05-25T08:59:36","slug":"explanation-to-standard-condition-for-gas-flow-measurement","status":"publish","type":"post","link":"https:\/\/www.hginstrument.com\/it\/explanation-to-standard-condition-for-gas-flow-measurement\/","title":{"rendered":"Spiegazione delle condizioni standard per la misurazione del flusso di gas"},"content":{"rendered":"
Explanation to standard condition for gas flow measurement:\u00a0<\/strong><\/p>\n About gas volume flow measurement,\u00a0standard condition is the temperature & pressure condition which is publicly\u00a0recognized for\u00a0trade settlement. For example, United states and latin America\u00a0take 15\u2103, 101.325 Kpa as standard condition. China\u00a0take 20\u2103, 101.325 Kpa as standard condition, other countries take 0\u2103, 101.325 Kpa as standard condition.<\/p>\n <\/p>\n \u00a0<\/strong>\u00a0 Gas volume changes accompany with temperature and pressure, it is the knowledge of the ideal gas state equation.<\/strong> In the actual application, For gas fluid, there are standard condition and process condition.<\/p>\n If the flow unit is Nm3\/h, it indicates the flow rate is at standard condition.<\/p>\n If the flow unit is Am3\/h, it indicates the flow rate is at process condition.<\/p>\n When writing flow unit, many customers are accustomed to omit the alphabet “N” or “A” in front of “m3”, it is less rigorous, so need to confirm the flow unit m3\/h is at standard condition or process condition.<\/p>\n