{"id":478,"date":"2021-01-15T08:52:45","date_gmt":"2021-01-15T00:52:45","guid":{"rendered":"http:\/\/201230ip92c2.adwebcloud.com\/?post_type=product&#038;p=478"},"modified":"2023-06-26T10:52:07","modified_gmt":"2023-06-26T02:52:07","slug":"hgcd-insertion-electromagnetic-flow-meter","status":"publish","type":"product","link":"https:\/\/www.hginstrument.com\/it\/flow-instrument\/hgcd-insertion-electromagnetic-flow-meter\/","title":{"rendered":"Misuratore di portata elettromagnetico ad inserimento HGCD"},"content":{"rendered":"<h5><strong>Features of HGCD Insertion Electromagnetic Flow Meter<\/strong><\/h5>\n<ul>\n<li>Reserve the advantages of pipeline type meter, strong universality and interchangeability<\/li>\n<li>If the process pressure is not more than 1.6Mpa, user can install or maintain under the process is running<\/li>\n<li>Compared to pipeline type meter, inserted type is easy to install and its price is cheaper than the pipeline type<\/li>\n<li>Can be installed on many kinds of pipe such as cast iron pipe, concrete pipe, plastic pipe<\/li>\n<li>If install the insertion type EMF flow meter on the concrete pipe, plastic pipe, need to use a pair of anchor ears for connecting the flow meter&#8217;s socket<\/li>\n<li>Without mechanical movement parts, lightweight, simple structure, long life span<\/li>\n<li>Local indication, LCD screen, has signal output terminals<\/li>\n<\/ul>\n<h5><\/h5>\n<h5>Technical data of HGCD Insertion Electromagnetic Flow Meter<\/h5>\n<table>\n<tbody>\n<tr style=\"background-color: #d8d8d8;\">\n<td width=\"151\"><\/td>\n<td width=\"192\">Integrate type<\/td>\n<td width=\"252\">Remote type<\/td>\n<\/tr>\n<tr>\n<td width=\"151\">Precisione<\/td>\n<td colspan=\"2\" width=\"444\">\u00b11.5%<\/td>\n<\/tr>\n<tr>\n<td width=\"151\">Dimensione<\/td>\n<td width=\"192\">DN150-DN3000<\/td>\n<td width=\"252\">DN150-DN3000<\/td>\n<\/tr>\n<tr>\n<td width=\"151\">Flange standard<\/td>\n<td colspan=\"2\" width=\"444\">GB9119 stainless steel<\/td>\n<\/tr>\n<tr>\n<td width=\"151\">Pressione nominale<\/td>\n<td colspan=\"2\" width=\"444\">1.6Mpa<\/td>\n<\/tr>\n<tr>\n<td width=\"151\">Alloggiamento del trasmettitore<\/td>\n<td colspan=\"2\" width=\"444\">die-casting aluminum alloy<\/td>\n<\/tr>\n<tr>\n<td width=\"151\">Sensor\/Transducer<\/td>\n<td colspan=\"2\" width=\"444\">Stainless steel body \/ PVDF liner<\/td>\n<\/tr>\n<tr>\n<td width=\"151\">Net weight<\/td>\n<td width=\"192\">About 6 kg<\/td>\n<td width=\"252\">About 8 kg<\/td>\n<\/tr>\n<tr>\n<td width=\"151\">Electrical conductivity<\/td>\n<td colspan=\"2\" width=\"444\">\u22655\u03bcs\/cm<\/td>\n<\/tr>\n<tr>\n<td width=\"151\">Electrode<\/td>\n<td colspan=\"2\" width=\"444\">316L, Hastelloy, Titanium<\/td>\n<\/tr>\n<tr>\n<td width=\"151\">Uscita<\/td>\n<td colspan=\"2\" width=\"444\">1KHz ( 2KHz ), 4-20mA<\/td>\n<\/tr>\n<tr>\n<td width=\"151\">Comunicazione<\/td>\n<td colspan=\"2\" width=\"444\">RS232, RS485, HART<\/td>\n<\/tr>\n<tr>\n<td width=\"151\">Alimentazione<\/td>\n<td colspan=\"2\" width=\"444\">220VAC, 24VDC, 3.6V lithium battery<\/td>\n<\/tr>\n<tr>\n<td width=\"151\">Resistente alle intemperie<\/td>\n<td width=\"192\">IP65 \/ IP67<\/td>\n<td width=\"252\">IP65 \/ IP67 \/ IP68<\/td>\n<\/tr>\n<tr>\n<td width=\"151\">Explosion pfoof<\/td>\n<td colspan=\"2\" width=\"444\">Exd IICT4<\/td>\n<\/tr>\n<tr>\n<td width=\"151\">Temperatura del fluido.<\/td>\n<td width=\"192\">80\u2103<\/td>\n<td width=\"252\">80\u2103 (120\u2103 optional)<\/td>\n<\/tr>\n<tr>\n<td width=\"151\">Storage Temp.<\/td>\n<td colspan=\"2\" width=\"444\">-40\u2103\uff5e+60\u2103<\/td>\n<\/tr>\n<tr>\n<td width=\"151\">Ambient Temp.<\/td>\n<td colspan=\"2\" width=\"444\">-20\u2103\uff5e+55\u2103<\/td>\n<\/tr>\n<tr>\n<td width=\"151\">Ripetibilit\u00e0<\/td>\n<td colspan=\"2\" width=\"444\">\u2264\u00b10.01%\u00a0 \/\u00a0 \u2264\u00b10.25%<\/td>\n<\/tr>\n<tr>\n<td width=\"151\">Analog output error<\/td>\n<td colspan=\"2\" width=\"444\">\u2264\u00b10.02mA<\/td>\n<\/tr>\n<tr>\n<td width=\"151\">Measure range<\/td>\n<td colspan=\"2\" width=\"444\">\u226410m\/s<\/td>\n<\/tr>\n<tr>\n<td width=\"151\">Ability for bury<\/td>\n<td width=\"192\"><\/td>\n<td width=\"252\">\u22645m only for IP68<\/td>\n<\/tr>\n<tr>\n<td width=\"151\">Electrical entry<\/td>\n<td width=\"192\">M20*1.5,\u00a0 G1\/2,\u00a0 NPT1\/2<\/td>\n<td width=\"252\"><\/td>\n<\/tr>\n<tr>\n<td width=\"151\">Transducer cable<\/td>\n<td width=\"192\"><\/td>\n<td width=\"252\">&lt;30m (special order for longer cable)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h5><\/h5>\n<p><strong>Wiring Terminal instruction of HGCD Insertion Electromagnetic Flow Meter&#8217;s compact converter as follow:<\/strong><\/p>\n<table>\n<tbody>\n<tr style=\"background-color: #d8d8d8;\">\n<td width=\"84\"><strong>Wiring terminal<\/strong><\/td>\n<td width=\"324\"><strong>Descrizione<\/strong><\/td>\n<td width=\"252\"><strong>Osservazione<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"84\">L 2<\/td>\n<td width=\"324\">Connect 220VAC \/ 24VDC &#8211;<\/td>\n<td width=\"252\"><\/td>\n<\/tr>\n<tr>\n<td width=\"84\">L 1<\/td>\n<td width=\"324\">Connect 220VAC \/ 24VDC +<\/td>\n<td width=\"252\"><\/td>\n<\/tr>\n<tr>\n<td width=\"84\">COM<\/td>\n<td width=\"324\">Current Output Ground for Flow Measurement<\/td>\n<td rowspan=\"2\" width=\"252\">Use for wiring of analog Current Output<\/td>\n<\/tr>\n<tr>\n<td width=\"84\">I +<\/td>\n<td width=\"324\">Current Output for Flow Measurement<\/td>\n<\/tr>\n<tr>\n<td width=\"84\">COM<\/td>\n<td width=\"324\">Frequency \/ Pulse Output Ground<\/td>\n<td rowspan=\"2\" width=\"252\">Use for wiring of frequency \/ pulse Output<\/td>\n<\/tr>\n<tr>\n<td width=\"84\">P+<\/td>\n<td width=\"324\">Frequency \/ Pulse Output for Bi-directional Flow<\/td>\n<\/tr>\n<tr>\n<td width=\"84\">AH<\/td>\n<td width=\"324\">Alarm Output for Upper Limit<\/td>\n<td rowspan=\"3\" width=\"252\">Use for wiring of alarm Output<\/td>\n<\/tr>\n<tr>\n<td width=\"84\">AL<\/td>\n<td width=\"324\">Alarm Output for Lower Limit<\/td>\n<\/tr>\n<tr>\n<td width=\"84\">COM<\/td>\n<td width=\"324\">Alarm Output Ground (connect with Current Output Ground or Frequency \/ Pulse Output Ground )<\/td>\n<\/tr>\n<tr>\n<td width=\"84\">FUSE<\/td>\n<td width=\"324\">Fuse for Power Supply<\/td>\n<td width=\"252\"><\/td>\n<\/tr>\n<tr>\n<td width=\"84\">T +<\/td>\n<td width=\"324\">Communication terminal (RS485 A+)<\/td>\n<td rowspan=\"3\" width=\"252\">Use for wiring of communication<\/td>\n<\/tr>\n<tr>\n<td width=\"84\">G<\/td>\n<td width=\"324\">RS232 Communication Ground<\/td>\n<\/tr>\n<tr>\n<td width=\"84\">T &#8211;<\/td>\n<td width=\"324\">Communication terminal (RS485 B-)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>Wiring Terminal instruction of HGCD Insertion Electromagnetic Flow Meter&#8217;s remote converter as follow:<\/strong><\/p>\n<table>\n<tbody>\n<tr style=\"background-color: #d8d8d8;\">\n<td width=\"84\"><strong>Wiring terminal<\/strong><\/td>\n<td width=\"300\"><strong>Descrizione<\/strong><\/td>\n<td width=\"288\"><strong>Osservazione<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"84\">SIG1<\/td>\n<td width=\"300\">Signal l<\/td>\n<td rowspan=\"7\" width=\"288\">For transducer of remote type<\/td>\n<\/tr>\n<tr>\n<td width=\"84\">SGND<\/td>\n<td width=\"300\">Signal Ground<\/td>\n<\/tr>\n<tr>\n<td width=\"84\">SIG2<\/td>\n<td width=\"300\">Signal 2<\/td>\n<\/tr>\n<tr>\n<td width=\"84\">DS1<\/td>\n<td width=\"300\">Shielded Exciting\u00a0 1<\/td>\n<\/tr>\n<tr>\n<td width=\"84\">DS2<\/td>\n<td width=\"300\">Shielded Exciting\u00a0 2<\/td>\n<\/tr>\n<tr>\n<td width=\"84\">EXT +<\/td>\n<td width=\"300\">Exciting Current &#8220;+&#8221;<\/td>\n<\/tr>\n<tr>\n<td width=\"84\">EXT &#8211;<\/td>\n<td width=\"300\">Exciting Current &#8220;-&#8220;<\/td>\n<\/tr>\n<tr>\n<td width=\"84\">VDIN<\/td>\n<td width=\"300\">24VDC Connect point (for 2-wire current output)<\/td>\n<td rowspan=\"3\" width=\"288\">Use for wiring of analog Current Output<\/td>\n<\/tr>\n<tr>\n<td width=\"84\">IOUT<\/td>\n<td width=\"300\">Analog Current Output<\/td>\n<\/tr>\n<tr>\n<td width=\"84\">ICOM<\/td>\n<td width=\"300\">Analog Current Output Ground<\/td>\n<\/tr>\n<tr>\n<td width=\"84\">POUT<\/td>\n<td width=\"300\">Flow Frequency (Pulse) Output<\/td>\n<td rowspan=\"2\" width=\"288\">Use for wiring of frequency (pulse) Output<\/td>\n<\/tr>\n<tr>\n<td width=\"84\">PCOM<\/td>\n<td width=\"300\">Frequency (Pulse) Output Ground<\/td>\n<\/tr>\n<tr>\n<td width=\"84\">ALMH<\/td>\n<td width=\"300\">Upper Limit Alarm Output<\/td>\n<td rowspan=\"3\" width=\"288\">Use for wiring of alarm Output<\/td>\n<\/tr>\n<tr>\n<td width=\"84\">ALML<\/td>\n<td width=\"300\">Lower Limit Alarm Output<\/td>\n<\/tr>\n<tr>\n<td width=\"84\">ACOM<\/td>\n<td width=\"300\">Alarm Output Ground<\/td>\n<\/tr>\n<tr>\n<td width=\"84\">TRX+<\/td>\n<td width=\"300\">Communication terminal (RS485 A+)<\/td>\n<td rowspan=\"3\" width=\"288\">Use for wiring of communication<\/td>\n<\/tr>\n<tr>\n<td width=\"84\">TRX-<\/td>\n<td width=\"300\">Communication terminal (RS485 B-)<\/td>\n<\/tr>\n<tr>\n<td width=\"84\">TCOM<\/td>\n<td width=\"300\">RS232 Communication Ground<\/td>\n<\/tr>\n<tr>\n<td width=\"84\">L<\/td>\n<td width=\"300\">Connect 220VAC \/ 24VDC +<\/td>\n<td width=\"288\"><\/td>\n<\/tr>\n<tr>\n<td width=\"84\">N<\/td>\n<td width=\"300\">Connect 220VAC \/ 24VDC &#8211;<\/td>\n<td width=\"288\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h5>Filed installation of HGCD Insertion Electromagnetic Flow Meter<\/h5>\n<p>Install Flow sensor on the metal pipeline\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Install Flow sensor on the plastic or cement pipeline<\/p>\n<p><img class=\"alignnone size-medium wp-image-481\" title=\"\" src=\"http:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/01\/insertion-installation-1-228x300.jpg\" alt=\"insertion installation 1\" width=\"228\" height=\"300\" srcset=\"https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/01\/insertion-installation-1-228x300.jpg 228w, https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/01\/insertion-installation-1.jpg 324w\" sizes=\"(max-width: 228px) 100vw, 228px\" \/>\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 <img class=\"alignnone size-medium wp-image-482\" title=\"\" src=\"http:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/01\/insertion-installation-2-228x300.jpg\" alt=\"insertion installation 2\" width=\"228\" height=\"300\" srcset=\"https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/01\/insertion-installation-2-228x300.jpg 228w, https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/01\/insertion-installation-2.jpg 326w\" sizes=\"(max-width: 228px) 100vw, 228px\" \/><\/p>\n<h5><\/h5>\n<h5><\/h5>\n<h5>Workshop Assembly line<\/h5>\n<h5>\u00a0 \u00a0<img class=\"alignnone wp-image-465 size-full\" title=\"workshop assembly line\" src=\"http:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/01\/workshop-assembly-line.jpg\" alt=\"workshop assembly line\" width=\"843\" height=\"564\" srcset=\"https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/01\/workshop-assembly-line.jpg 843w, https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/01\/workshop-assembly-line-300x201.jpg 300w, https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/01\/workshop-assembly-line-768x514.jpg 768w, https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/01\/workshop-assembly-line-600x401.jpg 600w\" sizes=\"(max-width: 843px) 100vw, 843px\" \/><\/h5>\n<h5><\/h5>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h5>Workshop Calibration line<\/h5>\n<p><img class=\"alignnone wp-image-467 size-full\" title=\"linea di calibrazione 1\" src=\"http:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/01\/calibration-line-1.jpg\" alt=\"\" width=\"1200\" height=\"675\" srcset=\"https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/01\/calibration-line-1.jpg 1200w, https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/01\/calibration-line-1-300x169.jpg 300w, https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/01\/calibration-line-1-768x432.jpg 768w, https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/01\/calibration-line-1-1024x576.jpg 1024w, https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/01\/calibration-line-1-600x338.jpg 600w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h5>Warehouse<\/h5>\n<p><img class=\"alignnone wp-image-464 size-full\" src=\"http:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/01\/warehouse.jpg\" alt=\"warehouse\" width=\"1091\" height=\"553\" srcset=\"https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/01\/warehouse.jpg 1091w, https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/01\/warehouse-300x152.jpg 300w, https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/01\/warehouse-768x389.jpg 768w, https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/01\/warehouse-1024x519.jpg 1024w, https:\/\/www.hginstrument.com\/wp-content\/uploads\/2021\/01\/warehouse-600x304.jpg 600w\" sizes=\"(max-width: 1091px) 100vw, 1091px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>Product description: <a href=\"https:\/\/www.hginstrument.com\/it\/hgcd-insertion-electromagnetic-flowmeter\/\"><span style=\"color: #ff0000;\">Misuratore di portata elettromagnetico ad inserimento HGCD<\/span><\/a> is mainly used to measure the volume flow of water, waste water, sewage, beverage, pulp, slurry, the fluid temperature usually not more than 120\u2103, fluid&#8217;s conductivity not less than 5\u03bcS\/cm. \u00a0It resolve the problem that it is difficult to install pipeline type meter on large size of pipe, meanwhile it saves a lot of cost compared to pipeline type meter. It is according to the principle of NIKURADS to measure average velocity of fluid, then get the volume of fluid flow.<br \/>\n<strong>Tag caldi:<\/strong>\u00a0 <a href=\"https:\/\/www.hginstrument.com\/it\/about\/\"><span style=\"color: #ff0000;\">Informazioni sul Gruppo Suyi<\/span><\/a>\uff0c<a href=\"https:\/\/www.hginstrument.com\/it\/flow-instrument\/\"><span style=\"color: #ff0000;\">Strumento di flusso<\/span><\/a>\uff0c<a href=\"https:\/\/www.hginstrument.com\/it\/level-transmitter\/\"><span style=\"color: #ff0000;\">Trasmettitore di livello<\/span><\/a>\uff0c<span style=\"color: #ff0000;\"><a style=\"color: #ff0000;\" href=\"https:\/\/www.hginstrument.com\/it\/water-flow-meter\/\">misuratore di portata dell'acqua<\/a><\/span><\/p>","protected":false},"featured_media":1439,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_cat":[75,215],"product_tag":[],"acf":[],"_links":{"self":[{"href":"https:\/\/www.hginstrument.com\/it\/wp-json\/wp\/v2\/product\/478"}],"collection":[{"href":"https:\/\/www.hginstrument.com\/it\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.hginstrument.com\/it\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hginstrument.com\/it\/wp-json\/wp\/v2\/comments?post=478"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hginstrument.com\/it\/wp-json\/wp\/v2\/media\/1439"}],"wp:attachment":[{"href":"https:\/\/www.hginstrument.com\/it\/wp-json\/wp\/v2\/media?parent=478"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.hginstrument.com\/it\/wp-json\/wp\/v2\/product_cat?post=478"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.hginstrument.com\/it\/wp-json\/wp\/v2\/product_tag?post=478"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}