electromagnetic flow meter

Technical data
Can serve Liquid or Gas fluid, usually be used to measure flow of steam, Vapor, Air and Natural gas.
Meter size: In-line type: DN25 – DN300
Wetted material option: SS304, SS316
Operation temperature: ≤250℃
Process connection: Wafer / Flange / Tri-clamp for In-line type
Measuring accuracy: 1.0 % – 1.5% of calibration range
Digital indicator: display instant flow, total flow
Power supply: 24VDC, Output: 4-20mA

features
1.Adjustable ON/OFF set-points
2.Hi or Lo flow alarm mode
3.Adjustable time delay
4.Relay status LED

Product Description

The electromagnetic flow meter is a highly reliable and accurate device used for measuring the flow of liquids and gases in various industrial and commercial applications. It is designed with advanced technology and high-quality components, making it durable and resistant to external factors such as temperature and pressure changes.

electromagnetic flow meter is an advanced flow measurement device designed to accurately measure and monitor the flow of various liquids and gases. With its cutting-edge technology and reliable performance, it has become the solution of choice in oil and gas, chemical processing, Research and development, water treatment and many other industries.

Our electromagnetic flow meter utilizes a state-of-the-art flow sensing technology that provides precise measurements with exceptional accuracy. It can accurately measure the flow rate of liquids and gases with flow rates ranging from 0.9 to 5125 m3/h. This high level of accuracy makes it an ideal solution for critical applications that require precise flow measurement.

Type: electromagnetic flow meter Output signal: 4-20 mA, Pulse/Frequency 2kHz(Default), 5KHz(Max)
Place of Origin: Jiangsu, China Incorporate type: -10℃- +60℃
Warranty: 21 months Supply voltage: 110/220VAC (100-240VAC), 50Hz/60Hz; 24VDC±10%
Customized support: OEM, ODM, OBM Digital communication: RS-485, support standard Mudbugs-RTU protocol; GPRS
Brand Name: SUYI GROUP Nominal pressure: 1MPa (DN15-DN800), 1.6MPa(DN15-DN800), 2.5MPa(DN15-DN600)
Model Number: other Sensor: 0℃- +80℃ or -25℃- +120℃ or +70℃- +250℃
Product Name: Electromagnetic Smart Digital Chemical Water Flow Meter Packaging Details: 1 Sets per package or as customer’s request
Nominal diameter: 3-3172mm Supply Ability: 1903 Set/Sets per Month
velocity range: 0-11m/s Quantity (sets): > 30
Degree of accuracy: ±0.5%R, ±1%R ( < DN20) Lead time (days): To be negotiated

 

 

 

 

 

 

electromagnetic flow meter FAQs Guide.

At the heart of our electromagnetic flow meter series lies a commitment to excellence, blending advanced sensor technology with user-friendly interfaces. From liquid to gas, our meters deliver unparalleled accuracy, empowering you to make informed decisions and streamline operations. As we usher in a new era of fluid measurement, we invite you to explore the limitless possibilities that our electromagnetic flow meters unlock – where precision meets performance, and innovation flows seamlessly.

1.About electromagnetic flow meter inventory
2.About electromagnetic flow meter warranty
3.How accurate is the electromagnetic flow meter?
4.About electromagnetic flow meter R&D capabilities
5.About electromagnetic flow meter origin
6.About electromagnetic flow meter patent
7.About electromagnetic flow meter technology
8.What is the explosion-proof rating of electromagnetic flow meter?
9.Does the electromagnetic flow meter require an external power source?
10.About electromagnetic flow meter overseas warehouse
11.Does the electromagnetic flow meter have multi-language display capabilities?
12.What are the maintenance methods for electromagnetic flow meter?
13.What are the common faults and solutions of electromagnetic flow meters?
14.About the development history of electromagnetic flow meter factory
15.What is the function of electromagnetic flow meter?

1.About electromagnetic flow meter inventory

Flow meter inventory is a system used to track and manage the flow meters used in industrial and commercial applications. It is used to monitor the performance of the flow meters, as well as to ensure that they are properly maintained and calibrated. The inventory system can also be used to track the cost of the flow meters, as well as to identify any potential problems or issues with the flow meters.

2.About electromagnetic flow meter warranty

Flow meter warranties vary depending on the manufacturer and the type of flow meter. Generally, warranties cover defects in materials and workmanship, and may also cover certain types of damages caused by normal use. Some warranties may also cover damages caused by improper installation or use. It is important to read the warranty information provided by the manufacturer to understand the specific coverage and limitations of the warranty.

About electromagnetic flow meter warranty

3.How accurate is the electromagnetic flow meter?

We are a professional electromagnetic flow meter company dedicated to providing high quality products and services.
The accuracy of a flow meter depends on the type of flow meter being used. Generally, most flow meters are accurate to within 1-2% of the actual flow rate. However, some flow meters can be more accurate than this, depending on the type and quality of the meter.

4.About electromagnetic flow meter R&D capabilities

Flow meter R&D capabilities refer to the ability of a company or organization to research, develop, and manufacture flow meters. This includes the ability to design, test, and manufacture flow meters that meet customer requirements and industry standards. It also includes the ability to develop new technologies and products to meet the changing needs of the industry. Companies with strong R&D capabilities are able to stay ahead of the competition and provide customers with the most advanced and reliable flow meters.

About electromagnetic flow meter R&D capabilities

5.About electromagnetic flow meter origin

The first flow meter was invented in 1832 by an Englishman named William Henry. He developed a device that used a float to measure the flow of water in a pipe. This device was the first of its kind and was the precursor to modern flow meters. Since then, flow meters have been used in a variety of industries to measure the flow of liquids, gases, and other materials. Today, flow meters are used in a variety of applications, from measuring the flow of water in a pipe to measuring the flow of oil in a refinery.

6.About electromagnetic flow meter patent

Flow meter patents are patents that cover the design and operation of flow meters. Flow meters are devices used to measure the rate of flow of a liquid or gas. Flow meters are used in a variety of industries, including water and wastewater treatment, oil and gas, and chemical processing. Flow meters are used to measure the flow rate of a fluid, the total volume of a fluid, and the pressure of a fluid. Flow meters can be mechanical, electrical, or optical. Flow meters can be used to measure the flow of liquids, gases, and steam.

About electromagnetic flow meter patent

7.About electromagnetic flow meter technology

Flow meter technology is a type of measurement technology used to measure the rate of flow of a fluid or gas. It is used in a variety of industries, including oil and gas, water and wastewater, and chemical processing. Flow meters measure the flow rate of a fluid or gas by measuring the pressure, velocity, or other physical properties of the fluid or gas. Flow meters can be used to measure the flow rate of liquids, gases, and steam. They are used to measure the flow rate of a variety of fluids, including water, oil, and chemicals. Flow meters are used in a variety of applications, including process control, energy management, and safety monitoring.

8.What is the explosion-proof rating of electromagnetic flow meter?

Our electromagnetic flow meter products undergo strict quality control to ensure customer satisfaction.
Explosion-proof ratings for flow meters vary depending on the type of meter and the application. Generally, flow meters are rated for Class I, Division 1, Groups C and D, or Class II, Division 1, Groups E, F, and G.

What is the explosion-proof rating of electromagnetic flow meter?

9.Does the electromagnetic flow meter require an external power source?

We adhere to the principle of quality first and have a complete production quality management system and quality inspection process.
It depends on the type of flow meter. Some flow meters are powered by an external power source, while others are powered by the flow of the liquid or gas being measured.

10.About electromagnetic flow meter overseas warehouse

Flow meter overseas warehouses are warehouses located in foreign countries that store flow meters and related products. These warehouses are used to store and distribute flow meters to customers in different countries. They are typically located in countries that have a large demand for flow meters, such as the United States, Canada, and Europe. The warehouses are usually owned and operated by the manufacturer of the flow meters, or by a third-party logistics provider. The warehouses are typically stocked with a variety of flow meters, including digital, analog, and ultrasonic flow meters. They also typically stock spare parts and accessories for the flow meters.

About electromagnetic flow meter overseas warehouse

11.Does the electromagnetic flow meter have multi-language display capabilities?

As one of the top electromagnetic flow meter manufacturers in China, we take this very seriously.
Yes, some flow meters have multi-language display capabilities. However, this feature is not available on all models. It is best to check with the manufacturer to see if the specific model you are interested in has this feature.

12.What are the maintenance methods for electromagnetic flow meter?

We focus on innovation and continuous improvement to maintain a competitive advantage.
1. Regularly check the flow meter for any signs of wear or damage.

2. Clean the flow meter regularly to ensure accurate readings.

3. Check the accuracy of the flow meter by performing calibration tests.

4. Replace any worn or damaged parts as soon as possible.

5. Ensure that the flow meter is properly installed and connected to the system.

6. Check the flow meter for any signs of corrosion or blockages.

7. Ensure that the flow meter is properly sealed to prevent any leaks.

8. Regularly check the flow meter for any signs of vibration or noise.

9. Ensure that the flow meter is properly calibrated and adjusted.

10. Regularly check the flow meter for any signs of leakage or clogging.

What are the maintenance methods for electromagnetic flow meter?

13.What are the common faults and solutions of electromagnetic flow meters?

We maintain a certain amount of R&D investment every year and continuously improve operational efficiency to provide better services to our cooperative customers.
Common faults and solutions of flow meters include:

1. Low accuracy: This is usually caused by incorrect installation or incorrect calibration. To solve this, check the installation and calibration of the flow meter and make sure it is correct.

2. Leakage: This is usually caused by a worn or damaged seal. To solve this, replace the seal with a new one.

3. Clogging: This is usually caused by debris or other particles blocking the flow meter. To solve this, clean the flow meter and remove any debris or particles.

4. Corrosion: This is usually caused by exposure to corrosive liquids or gases. To solve this, replace any corroded parts and use a corrosion-resistant material for the flow meter.

14.About the development history of electromagnetic flow meter factory

The flow meter factory was established in the early 1990s. It was founded by a group of engineers and technicians who had extensive experience in the design and manufacture of flow meters. The company initially focused on the production of mechanical flow meters, but soon expanded its product range to include electronic flow meters. Over the years, the company has developed a wide range of flow meters for various applications, including industrial, commercial, and residential. The company has also developed a range of software and hardware solutions for flow measurement and control. Today, the company is a leading manufacturer of flow meters and related products, and is recognized as a leader in the industry.

About the development history of electromagnetic flow meter factory

15.What is the function of electromagnetic flow meter?

Our company has many years of electromagnetic flow meter experience and expertise.
A flow meter is a device used to measure the flow rate or quantity of a gas or liquid moving through a pipe. It is used to measure the rate of flow of a liquid or gas in a closed conduit. Flow meters are used in a variety of industries, including water and wastewater treatment, oil and gas, and chemical processing.

 

Tag:flo-tech flow meter,chemical resistant flow meter,gas turbine flow meter,irrigation system flow meter,tri clamp flow meter

 

FAQ

Answer : Please send your question or enquiry to our email: sales@hginstrument.com, we will forward the questions to the related engineer.

Answer :  Please communicate with the sales about the return procedure before returning product.

Answer :  The delivery time depends on the order quantity and product specification.  If the product’s specification is conventional ( not special ),  delivery time is 5 or 7 working days for order quantity ≤ 10 pieces;  delivery time is 2 or 3 working weeks for order quantity 15 ~ 30 pieces. 

Answer :  by Courier,  by Sea or by Air

Answer :  Yes,  Generally warranty is one year.

Answer :  From year 2015  to year 2021,  average annual sales is RMB 350 million ( about USD 54.7 million )