HLS-2000UF In-pipeline Ultrasonic Flow Meter

 

Product name:

In-pipeline Ultrasonic Flow Meter


Application: Volumetric flow measurement of all kinds of clear liquids

 

Advantages: Easy installation and configuration; OEM acceptable!
Tel: 86-517-86885008

Email: sales@hginstrument.com

Product Description

 

Technical data of Flow transmitter

Item

Description

Converter

Principle

Time-difference method

Accuracy

Inline type: flow meter:±0.5%; heat meter: ±1.0%

Clamp on type:flow meter:±1.0%; heat meter:±2.0%

Insertion type: flow meter:±1.0%; heat meter:±2.0%

Operation

4-key manipulation with magnetic pen touch or finger touch; simulation keyboard software

Output

One way 4~20mA analog output,electric resistance:0~1k,accuracy:0.1%

One way OCT pulse signal output

One way Relay output

Input

3 way 4~20mA analog input,accuracy:0.1%;Acquisition signal of temperature,press and liquid level

Achieve heat measurement by connecting 3-wired PT100 temperature transducers

Data interface

RS485 serial interface,upgraded by computer, support MODBUS communication protocol

Special cable

Twisted-pair shielded cable and cable length should be no more than 50 m .Transmission distance can achieve 1 km, if select the RS 485 interface

Pipeline

Pipe mateial

Steel, stainless, cast iron ,copper,cement,PVC,aluminum, glass steel,etc.

Pipe diameter

DN15mm~DN6000mm

Straight pipe

requirement

Transducers installation points should be:10 diameters’ straight pipeline from upstream transducer; 5 diameters’ straight pipeline from the downstream transducer;30 diameters’ straight pipeline from the pump

Fluid

Liquid type

Single liquid that can conduct sound wave, such as water, seawater, sewage, plant effluent, chemicals, alcohol, beer, oil, etc.

Fluid Temp.

-30℃~160℃

Turbidity

≤10000ppm,with little bubble

Fluid velocity

0m/s~7m/s

Working

Environment

Temperature

Converter:-20℃~60℃; Transducer:-30℃~160℃

Humidity

Both of the converter and transducers can work under water, depth underwater ≤2m. (After completely sealing )

Power supply

DC8~36V;  AC85~264V(optional) 1.5W

Power  Consumption:  1.5W

   

Company introduction