{"id":1712,"date":"2021-08-13T09:26:44","date_gmt":"2021-08-13T01:26:44","guid":{"rendered":"http:\/\/201230ip92c2.adwebcloud.com\/?post_type=product&p=1712"},"modified":"2021-10-11T15:55:13","modified_gmt":"2021-10-11T07:55:13","slug":"thermocouple","status":"publish","type":"product","link":"https:\/\/www.hginstrument.com\/pt\/temperature-instrument\/thermocouple\/","title":{"rendered":"Termopar"},"content":{"rendered":"
Tipo de termopar:<\/strong><\/p>\n <\/p>\n Estrutura da sonda:<\/strong><\/p>\n <\/p>\n Informa\u00e7\u00f5es sobre a encomenda:<\/strong> <\/p>\n <\/p>\n <\/p>","protected":false},"excerpt":{"rendered":" O termopar \u00e9 constitu\u00eddo por um elemento t\u00e9rmico, um material de isolamento (cer\u00e2mica ou MgO) e um tubo de prote\u00e7\u00e3o.<\/p>","protected":false},"featured_media":1689,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_cat":[1540,1542],"product_tag":[],"acf":[],"_links":{"self":[{"href":"https:\/\/www.hginstrument.com\/pt\/wp-json\/wp\/v2\/product\/1712"}],"collection":[{"href":"https:\/\/www.hginstrument.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.hginstrument.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hginstrument.com\/pt\/wp-json\/wp\/v2\/comments?post=1712"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hginstrument.com\/pt\/wp-json\/wp\/v2\/media\/1689"}],"wp:attachment":[{"href":"https:\/\/www.hginstrument.com\/pt\/wp-json\/wp\/v2\/media?parent=1712"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.hginstrument.com\/pt\/wp-json\/wp\/v2\/product_cat?post=1712"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.hginstrument.com\/pt\/wp-json\/wp\/v2\/product_tag?post=1712"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}\n\n
\n C\u00f3digo de tipo<\/td>\n Material do fio t\u00e9rmico<\/td>\n Gama de medi\u00e7\u00e3o<\/td>\n Valor de toler\u00e2ncia<\/td>\n<\/tr>\n \n B<\/td>\n PtRh30-PtRh<\/td>\n 600 ~ 1700 \u2103<\/td>\n \u00b11,5 \u2103 ou \u00b10,25% t<\/td>\n<\/tr>\n \n S<\/td>\n PtRh10-Pt<\/td>\n 0 ~ 1600 \u2103<\/td>\n \u00b11,5 \u2103 ou \u00b10,25% t<\/td>\n<\/tr>\n \n K<\/td>\n Nicr-NiSi<\/td>\n 0 ~ 1200 \u2103<\/td>\n \u00b12,5 \u2103 ou \u00b10,75% t<\/td>\n<\/tr>\n \n E<\/td>\n Nicr-CuNi<\/td>\n 0 ~ 800 \u2103<\/td>\n \u00b12,5 \u2103 ou \u00b10,75% t<\/td>\n<\/tr>\n \n T<\/td>\n Cu-cuNi<\/td>\n -40 ~ 350 \u2103<\/td>\n \u00b11 \u2103 ou \u00b10,75% t<\/td>\n<\/tr>\n \n J<\/td>\n Te-CuNi<\/td>\n 0 ~ 800 \u2103<\/td>\n \u00b12,5 \u2103 ou \u00b10,75% t<\/td>\n<\/tr>\n \n N<\/td>\n NiCrSi-NiSi<\/td>\n 0 ~ 1200 \u2103<\/td>\n \u00b12,5 \u2103 ou \u00b10,75% t<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n
<\/p>\n
\n\u25cf Meio medido:?
\n\u25cf Gama de temperaturas:?
\n\u25cf Tipo de sensor: ?
\n\u25cf Di\u00e2metro do sensor: ?
\n\u25cf Liga\u00e7\u00e3o do processo:?
\n\u25cf Comprimento de inser\u00e7\u00e3o e comprimento total:?
\n\u25cf Material: ?<\/p>\n