{"id":648,"date":"2021-02-04T10:01:07","date_gmt":"2021-02-04T02:01:07","guid":{"rendered":"http:\/\/201230ip92c2.adwebcloud.com\/?post_type=product&p=648"},"modified":"2023-07-12T17:08:42","modified_gmt":"2023-07-12T09:08:42","slug":"battery-powered-electromagnetic-flow-meter","status":"publish","type":"product","link":"https:\/\/www.hginstrument.com\/pt\/flow-instrument\/battery-powered-electromagnetic-flow-meter\/","title":{"rendered":"Medidor de caudal eletromagn\u00e9tico alimentado por bateria"},"content":{"rendered":"
Introduction to Battery Powered Electromagnetic Flow Meter’s W803E display pannel<\/h5>\n

 <\/p>\n

\"w803e<\/p>\n

 <\/p>\n

<\/h5>\n
Infrared remote controller for operating on W803E display panel of Battery Powered Electromagnetic Flow Meter<\/strong><\/h5>\n

 <\/p>\n

\"infrared<\/p>\n

 <\/p>\n

Technical data of Battery Powered Electromagnetic Flow Meter<\/h5>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
Suitable Diameter<\/td>\nDN25~DN2600 (below DN25 non-standard)<\/td>\n<\/tr>\n
Electrode quantity<\/td>\n3pcs ( a pair of measuring electrode and a ground electrode)<\/td>\n<\/tr>\n
Suitable Fluid<\/td>\nLiquid with conductivity not less than 5 \u03bcs\/cm<\/td>\n<\/tr>\n
Measuring Range<\/td>\n0.5~10m\/s (extendable to 15m\/s)<\/td>\n<\/tr>\n
Upper Limit of Span<\/td>\n0.5~10m\/s. 1~5m\/s recommended<\/td>\n<\/tr>\n
Exatid\u00e3o<\/td>\n0.5%, 1.0% of F.S.<\/td>\n<\/tr>\n
Repetibilidade<\/td>\nBetter than 0.25%<\/td>\n<\/tr>\n
Display of Converter<\/td>\nDisplay : Flow rate ( 4-digits), Totalizer (9-digits), Velocity, Alarm status by LCD ( LED-option)<\/td>\n<\/tr>\n
Flow unit: L\/h, L\/m, L\/s, m3\/h, m3\/min, m3\/s,
\nUSG\/h, USG\/min,USG\/s ( USG is us Gallon on request )<\/td>\n<\/tr>\n
Flow direction : selectable by program<\/td>\n<\/tr>\n
3 Digits display below of decimal points.<\/td>\n<\/tr>\n
K-factor: 5 digits.<\/td>\n<\/tr>\n
Programming language: English, Chinese<\/td>\n<\/tr>\n
Structure option: Compact type; Remote Type<\/td>\n<\/tr>\n
Power supply configuration<\/td>\nLithium battery pack, 3.6V\/19AH (only support flow meter exciting and display, not support analog output or communication<\/span>)<\/td>\n<\/tr>\n
Fun\u00e7\u00e3o opcional<\/td>\nExternal powered 12VDC \/ 24VDC, RS485 communication<\/td>\n<\/tr>\n
Operation Pressure<\/td>\n1.0MPa, 1.6MPa, 4.0MPa, 16MPa (Special)<\/td>\n<\/tr>\n
Temperatura de funcionamento<\/td>\nDepends on liner material<\/td>\n<\/tr>\n
Temperatura ambiente<\/td>\nSensor -40\u00b0C ~80\u00b0C. transducer -10\u00b0C ~50\u00b0C<\/td>\n<\/tr>\n
Ambient Humidity<\/td>\n\u2264 85%RH (at 20 \u2103)<\/td>\n<\/tr>\n
Consumo de energia<\/td>\n\u2264 8W<\/td>\n<\/tr>\n
Wheather-proof<\/td>\nCompact type: IP65. Remote type: sensor IP68, transducer IP65.<\/td>\n<\/tr>\n
Electrode material option<\/td>\n316L (stainless steel), Hastelloy C, Hastelloy B, Titanium, Tantalum<\/td>\n<\/tr>\n
Liner material option<\/td>\nPTFE, Soft rubber, Hard rubber, F46, FS, PUR.<\/td>\n<\/tr>\n
Meter tube material option<\/td>\nCarbon steel, SS304<\/td>\n<\/tr>\n
Tipo de liga\u00e7\u00e3o<\/td>\nFlange connection, Tri-clamp<\/td>\n<\/tr>\n
Flange standard option<\/td>\nGB9119-88 (DIN2051, BS4504), JIS, ANSI<\/td>\n<\/tr>\n
\u00c0 prova de explos\u00e3o<\/td>\nExd mb IICT6 Gb<\/td>\n<\/tr>\n
Certificate<\/td>\nISO9001:2015, ISO14001:2015, SIL 3, OHSAS18001:2007<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

 <\/p>\n

Menu list of Battery Powered Electromagnetic Flow Meter<\/strong><\/p>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
Menu code<\/strong><\/td>\nMenu level<\/strong><\/td>\nDescri\u00e7\u00e3o<\/strong><\/td>\n<\/tr>\n
Parameters Set<\/td>\nLevel 1<\/td>\nHas submenus<\/td>\n<\/tr>\n
Clr Total Rec<\/td>\nTotal flow clearing<\/td>\n<\/tr>\n
Flow Total Rec<\/td>\nMonth total flow record<\/td>\n<\/tr>\n
Heat Total Rec<\/td>\nMonth heat flow record<\/td>\n<\/tr>\n
Error Record<\/td>\nError record<\/td>\n<\/tr>\n
Operate Mode<\/td>\nLevel 2, \u00a0( in Level 1<\/p>\n

Menu \u201dParameters Set\u201d)<\/td>\n

Has submenus<\/td>\n<\/tr>\n
Flow Parameters<\/td>\nHas submenus<\/td>\n<\/tr>\n
Output Parameter<\/td>\nHas submenus<\/td>\n<\/tr>\n
Sensor Paramet<\/td>\nHas submenus<\/td>\n<\/tr>\n
Linearization<\/td>\nHas submenus<\/td>\n<\/tr>\n
Tempert Param.<\/td>\nHas submenus<\/td>\n<\/tr>\n
Comunica\u00e7\u00e3o<\/td>\nHas submenus<\/td>\n<\/tr>\n
Date Parameters<\/td>\nHas submenus<\/td>\n<\/tr>\n
Factory Adjust<\/td>\nHas submenus<\/td>\n<\/tr>\n
Total Parameter<\/td>\nHas submenus<\/td>\n<\/tr>\n
Pressure Param.<\/td>\nHas submenus<\/td>\n<\/tr>\n
Test Parameter<\/td>\nHas submenus<\/td>\n<\/tr>\n
Operate Mode<\/td>\nLevel 3, \u00a0( in Level 2<\/p>\n

Menu \u201d Operate Mode\u201d)<\/td>\n

Flow measure mode select setting<\/p>\n

Option: Flow only, Flow+Pressure, Flow+Temperature<\/td>\n<\/tr>\n

Interval Time<\/td>\nMeasure time interval setting<\/td>\n<\/tr>\n
Meter Dormancy<\/td>\nMeter dormancy password setting<\/td>\n<\/tr>\n
Measure Mode<\/td>\nHeat measuring mode select setting<\/td>\n<\/tr>\n
LCD off Enable<\/td>\nLCD screen shutdown mode Enable<\/td>\n<\/tr>\n
Sensor Size<\/td>\nLevel 3, \u00a0( in Level 2<\/p>\n

Menu \u201d Flow Parameters\u201d)<\/td>\n

Meter pipe size selection<\/td>\n<\/tr>\n
Flow Unit<\/td>\nFlow unit selection<\/td>\n<\/tr>\n
Flow Range<\/td>\nFlow range setting<\/td>\n<\/tr>\n
Flow Directon<\/td>\nFlow direction selection<\/td>\n<\/tr>\n
Flow Zero CRC<\/td>\nFlow zero point correct<\/td>\n<\/tr>\n
Flow Cutoff<\/td>\nSmall flow signal cut-off setting<\/td>\n<\/tr>\n
Flow FilterTime<\/td>\nMeasure damping time setting<\/td>\n<\/tr>\n
Reverse Flow En<\/td>\nReverse flow measuring Enable<\/td>\n<\/tr>\n
Starting Value<\/td>\nThreshold value of frequently measuring<\/td>\n<\/tr>\n
High Alm. Limit<\/td>\nFlow rate High limit Alarm<\/td>\n<\/tr>\n
Heat Display<\/td>\nHeat display select setting<\/td>\n<\/tr>\n
Pulse Output En<\/td>\nLevel 3, \u00a0( in Level 2<\/p>\n

Menu \u201d Output Parameter\u201d)<\/td>\n

Pulse output Enable<\/td>\n<\/tr>\n
Pulse Unit<\/td>\nPulse output unit<\/td>\n<\/tr>\n
Pulse Factor<\/td>\nSetting Pulse equivalent<\/td>\n<\/tr>\n
Pulse Width<\/td>\nSetting pulse width<\/td>\n<\/tr>\n
Sensor Factor<\/td>\nLevel 3, ( in Level 2<\/p>\n

Menu \u201dSensor Paramet.\u201d)<\/td>\n

Sensor coefficient setting<\/td>\n<\/tr>\n
Excitation Time<\/td>\nExcitation Mode selection<\/td>\n<\/tr>\n
Sensor Coding<\/td>\nSensor Code<\/td>\n<\/tr>\n
Empertypipe Value<\/td>\nThreshold of Empty pipe alarm<\/td>\n<\/tr>\n
Emperty Zero CRC<\/td>\nEmpty pipe zero point correct<\/td>\n<\/tr>\n
Emperty Range CRC<\/td>\nEmpty pipe full point correct<\/td>\n<\/tr>\n
System Alarm En<\/td>\nSystem alarm Enable<\/td>\n<\/tr>\n
Linearizati. Ena<\/td>\nLevel 3, \u00a0( in Level 2<\/p>\n

Menu \u201d Linearization\u201d)<\/td>\n

Flow linearity correct Enable<\/td>\n<\/tr>\n
Speed Point 1<\/td>\nFlow point1<\/td>\n<\/tr>\n
Speed Value 1<\/td>\nFlow point1\u2019s corrected value<\/td>\n<\/tr>\n
Speed Point 2<\/td>\nFlow point2<\/td>\n<\/tr>\n
Speed Value 2<\/td>\nFlow point2\u2019s corrected value<\/td>\n<\/tr>\n
Speed Point 3<\/td>\nFlow point3<\/td>\n<\/tr>\n
Speed Value 3<\/td>\nFlow point3\u2019s corrected value<\/td>\n<\/tr>\n
Speed Point 4<\/td>\nFlow point4<\/td>\n<\/tr>\n
Speed Value 4<\/td>\nFlow point4\u2019s corrected value<\/td>\n<\/tr>\n
Speed Point 5<\/td>\nFlow point5<\/td>\n<\/tr>\n
Speed Value 5<\/td>\nFlow point5\u2019s corrected value<\/td>\n<\/tr>\n
Speed Point 6<\/td>\nFlow point6<\/td>\n<\/tr>\n
Speed Value 6<\/td>\nFlow point6\u2019s corrected value<\/td>\n<\/tr>\n
Speed Point 7<\/td>\nFlow point7<\/td>\n<\/tr>\n
Speed Value 7<\/td>\nFlow point7\u2019s corrected value<\/td>\n<\/tr>\n
Speed Point 8<\/td>\nFlow point8<\/td>\n<\/tr>\n
Speed Value 8<\/td>\nFlow point8\u2019s corrected value<\/td>\n<\/tr>\n
Finish Point<\/td>\nFlow velocity correct of the flow end point<\/td>\n<\/tr>\n
Heat Unit<\/td>\nLevel 3, \u00a0( in Level 2<\/p>\n

Menu \u201d Tempert Param.\u201d)<\/td>\n

Heat unit selection<\/td>\n<\/tr>\n
Sensor Position<\/td>\nFlow sensor position setting<\/td>\n<\/tr>\n
Temperat. Filter<\/td>\nTemperature sensor filtering time selection<\/td>\n<\/tr>\n
Ent. T Zero CRC<\/td>\nInlet temperature zero point correcting<\/td>\n<\/tr>\n
Ent. T Range CRC<\/td>\nInlet temperature full span point correcting<\/td>\n<\/tr>\n
Out. T Zero CRC<\/td>\nOutlet temperature zero point correcting<\/td>\n<\/tr>\n
Out. T Range CRC<\/td>\nOutlet temperature full span point correcting<\/td>\n<\/tr>\n
Pressure Range<\/td>\nBattery power supply heat meter is set at 0.6MP and 1.6MP pressures according to the<\/p>\n

industry standard CJ128-2007 of the People’s Republic of China.<\/td>\n<\/tr>\n

Ent. Temp. Calic.<\/td>\nInlet temperature correcting factor<\/td>\n<\/tr>\n
Out. Temp. Calic.<\/td>\nOutlet temperature correcting factor<\/td>\n<\/tr>\n
CommAddres<\/td>\nLevel 3, \u00a0( in Level 2<\/p>\n

Menu \u201d Communication\u201d)<\/td>\n

Communication address range is from 01 to 199. address 0 is reserved.<\/td>\n<\/tr>\n
Communicat.Gap<\/td>\nCommunication Gap is used to send data to communication terminal, set range: 01\uff5e199 s.<\/td>\n<\/tr>\n
IrDA Port Ena<\/td>\nThis menu is temporarily reserved.<\/td>\n<\/tr>\n
Communicat.rate<\/td>\nBaud rate setting<\/td>\n<\/tr>\n
Communicat.check<\/td>\nInstrument is no parity of standard MODBUS check mode. Users can choose odd parity or even parity as needed.<\/td>\n<\/tr>\n
YEAR<\/td>\nLevel 3, \u00a0( in Level 2<\/p>\n

Menu \u201d Date Parameters\u201d)<\/td>\n

Year-time setting<\/td>\n<\/tr>\n
MONTH<\/td>\nMonth-time setting<\/td>\n<\/tr>\n
DAY<\/td>\nDay-setting<\/td>\n<\/tr>\n
HOUR<\/td>\nHour-time setting<\/td>\n<\/tr>\n
MINUTE<\/td>\nMinute-time setting<\/td>\n<\/tr>\n
SECOND<\/td>\nSecond-time setting<\/td>\n<\/tr>\n
Language<\/td>\nLevel 3, \u00a0( in Level 2<\/p>\n

Menu \u201d Factory Adjust\u201d)<\/td>\n

Display language selection (Chinese \/ English)<\/td>\n<\/tr>\n
Meter Factor<\/td>\nMeter\u2019s calibration coefficient (factory setting)<\/td>\n<\/tr>\n
Meter Correct<\/td>\nMeter\u2019s correct coefficient (factory setting)<\/td>\n<\/tr>\n
Enter Password1<\/td>\nPassword setting (permit enter menu \u201cparameter set\u201d)<\/td>\n<\/tr>\n
Meter code1<\/td>\nCode records of the time the converter leaves the factory and the number.<\/td>\n<\/tr>\n
Meter code2<\/td>\n<\/tr>\n
Meter code3<\/td>\n<\/tr>\n
Meter code4<\/td>\n<\/tr>\n
Multiplier<\/td>\nThis menu is temporarily reserved.<\/td>\n<\/tr>\n
Factory Logo<\/td>\nFactory logo Enable<\/td>\n<\/tr>\n
Flow Total Unit<\/td>\nLevel 3, ( in Level 2<\/p>\n

Menu \u201d Total Parameter\u201d)<\/td>\n

Total flow integrating unit selection<\/td>\n<\/tr>\n
Heat Total unit<\/td>\nTotal heat integrating unit selection<\/td>\n<\/tr>\n
Clear Total Key<\/td>\nPassword setting (permit total clear)<\/td>\n<\/tr>\n
FWD Total Low<\/td>\nLow bits of forward total flow<\/td>\n<\/tr>\n
FWD Total High<\/td>\nHigh bits of forward total flow<\/td>\n<\/tr>\n
REV Total Low<\/td>\nLow bits of reverse total flow<\/td>\n<\/tr>\n
REV Total High<\/td>\nHigh bits of reverse total flow<\/td>\n<\/tr>\n
Heat Total Low<\/td>\nLow bits of heat total<\/td>\n<\/tr>\n
Heat Total High<\/td>\nHigh bits of heat total<\/td>\n<\/tr>\n
Total Display<\/td>\nTotal display mode selection<\/td>\n<\/tr>\n
Pressure Unit<\/td>\nLevel 3, \u00a0( in Level 2<\/p>\n

Menu \u201d Pressure Param\u201d)<\/td>\n

Pressure unit selection<\/td>\n<\/tr>\n
P_Sensor Excit<\/td>\nPressure exiciting current selection<\/td>\n<\/tr>\n
Pressure Gain<\/td>\nPressure gain setting<\/td>\n<\/tr>\n
Pressure Zero CRC<\/td>\nPressure zero point correcting<\/td>\n<\/tr>\n
Press. Gain CRC<\/td>\nPressure full point correcting<\/td>\n<\/tr>\n
Set Velocity<\/td>\nLevel 3, \u00a0( in Level 2<\/p>\n

Menu \u201d Test Parameter\u201d)<\/td>\n

This menu is temporarily reserved.<\/td>\n<\/tr>\n
Set Ent.Tempe.<\/td>\nThis menu is temporarily reserved.<\/td>\n<\/tr>\n
Set Exi.Tempe.<\/td>\nThis menu is temporarily reserved.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

 <\/p>\n

Oficina Linha de montagem<\/h5>\n
\u00a0 \u00a0\"linha<\/h5>\n
<\/h5>\n

 <\/p>\n

Oficina Linha de calibra\u00e7\u00e3o<\/h5>\n

\"\"<\/p>\n

 <\/p>\n

Armaz\u00e9m<\/h5>\n

\"armaz\u00e9m\"<\/p>\n

 <\/p>\n

Filed application of ElectroMagnetic flow meter<\/h5>\n

Drink water flow measurement\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0Waste water flow measurement\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0Slurry flow measurement<\/p>\n

\"field<\/p>\n

 <\/p>\n

 <\/p>","protected":false},"excerpt":{"rendered":"

Battery powered Electromagnetic flow meter<\/a><\/strong> is mainly used on the sites which have no external power supply, to measure the volume flow of water, waste water, sewage, beverage, slurry, the fluid temperature usually not more than 120\u2103, fluid’s conductivity not less than 5\u03bcS\/cm.<\/p>\n

Standard configuration of Battery Powered Electromagnetic Flow Meter: Lithium battery powered (3.6V \/ 19AH),\u00a0 can support flow meter continuously working for about 5 years.
\nHot Tags:<\/strong>
Sobre o Grupo Suyi<\/span><\/a>\uff0cInstrumento de caudal<\/a><\/span>\uff0cTransmissor de n\u00edvel<\/a><\/span>\uff0cmedidor de caudal de \u00e1gua<\/a><\/span><\/p>","protected":false},"featured_media":2435,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_cat":[75,467],"product_tag":[],"acf":[],"_links":{"self":[{"href":"https:\/\/www.hginstrument.com\/pt\/wp-json\/wp\/v2\/product\/648"}],"collection":[{"href":"https:\/\/www.hginstrument.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.hginstrument.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hginstrument.com\/pt\/wp-json\/wp\/v2\/comments?post=648"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hginstrument.com\/pt\/wp-json\/wp\/v2\/media\/2435"}],"wp:attachment":[{"href":"https:\/\/www.hginstrument.com\/pt\/wp-json\/wp\/v2\/media?parent=648"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.hginstrument.com\/pt\/wp-json\/wp\/v2\/product_cat?post=648"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.hginstrument.com\/pt\/wp-json\/wp\/v2\/product_tag?post=648"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}