Sensor de caudal de boquilla

La boquilla adopta la estructura de contorno de arco circular, por lo que su pérdida de presión es pequeña, la longitud de tubo recto que requiere la instalación de la boquilla es corta y la precisión es alta.

Descripción del producto

Principio:

The design of nozzle is based on throttling principle of fluid dynamics. When the fluid pass the nozzle, the flow beam will contract, which make the flow velocity quicken, static pressure reduce, hence, the pressure difference is produced between the upstream and the downstream of the nozzle. The larger the flow rate is, the larger the produced pressure difference is. And the square root of the pressure difference is in direct proportion to the flow rate.

Structure Diagram:

 

structure diagram

Product Features:

● Simple structure,  stable and reliable performance
● Low pressure loss
● International standard adopted to calculate and process, test based on JJG640-94.
● High accuracy, good repeatability, stable outflow coefficient
● Flow measurement of liquid, gas or steam
● High temperature resistance, high pressure resistance and impact resistance

 

Technical Parameters:
Standard Nozzle
Medio aplicable Steam with high temperature or high pressure, water, liquid, gas
Diámetro nominal DN50 ~ DN500
Working pressure ≤ 42 Mpa
Working temperature -50 ~ 650℃
Pressure tapping Angle tapping
Montaje Flanged type, wafer type, welding type
Executive standard ISO 5167: GB / T2624
Precisión ± 1.0%
Meter tube material Carbon steel,  Stainless steel
Nozzle material SS304, SS316

 

Long Neck Nozzle

Medio aplicable Steam with high temperature or high pressure, water, liquid, gas
Diámetro nominal DN50 ~ DN500
Working pressure ≤ 42 Mpa
Working temperature -50 ~ 650℃
Pressure tapping D-D/2 tapping
Montaje Flanged type, wafer type, welding type
Executive standard ISO 5167: GB / T2624
Precisión ± 2.0%
Meter tube material Carbon steel,  Stainless steel
Nozzle material SS304, SS316

 

Installation and Using

1) Avoid the process pressure becoming negative pressure.
2) Prevent the nozzle’s flow field from the large motor, transformer.
3) Select the installation position which has no or slight vibration.
4) The location shall be easy grounding for the flow sensor.
5) Avoid the direct sunlight.
6) Avoid the environment where there is high concentrations of corrosive gas.
7) The requirement to the upstream / downstream straight pipe length specified in the calculation sheet shall be met.
8) The flow sensor can be installed on horizontal pipe, vertical pipe or inclined pipe, but the pipeline must be fully filled with the fluid.
9) The upstream / downstream straight pipe must be circular, the inner wall of pipeline shall be clean, no pits and deposit substance.
10) The installation of pressure tapping tube  shall be comply with the industry standard.
11) Installation diagram of nozzle flow sensor for gas fluid and steam fluid as follow:

installation diagram

 

Diagram of straight pipe length at upstream / downstream:

 

straight pipe requirement

 

 

 

PREGUNTAS FRECUENTES

Answer : Envíe su pregunta o consulta a nuestro correo electrónico: sales@hginstrument.com, remitiremos las preguntas al ingeniero correspondiente.

Answer : Por favor comuníquese con el departamento de ventas sobre el procedimiento de devolución antes de devolver el producto.

Answer : El plazo de entrega depende de la cantidad del pedido y de la especificación del producto. Si la especificación del producto es convencional ( no especial ),  El plazo de entrega es de 5 ó 7 días laborables para cantidad del pedido ≤ 10 piezas;  El plazo de entrega es de 2 ó 3 semanas laborables para cantidad del pedido 15 ~ 30 piezas. 

Answer por correo, por mar o por aire

Answer : Sí, generalmente la garantía es de un año.

Answer : De 2015 a 2021, el promedio de ventas anuales es de 350 millones de RMB (unos 54,7 millones de USD).