Sensor de caudal de boquilla
La boquilla adopta la estructura de contorno de arco circular, por lo que su pérdida de presión es pequeña, la longitud de tubo recto que requiere la instalación de la boquilla es corta y la precisión es alta.
Descripción del producto
Principio:
The design of nozzle is based on throttling principle of fluid dynamics. When the fluid pass the nozzle, the flow beam will contract, which make the flow velocity quicken, static pressure reduce, hence, the pressure difference is produced between the upstream and the downstream of the nozzle. The larger the flow rate is, the larger the produced pressure difference is. And the square root of the pressure difference is in direct proportion to the flow rate.
Structure Diagram:
Product Features:
● Simple structure, stable and reliable performance
● Low pressure loss
● International standard adopted to calculate and process, test based on JJG640-94.
● High accuracy, good repeatability, stable outflow coefficient
● Flow measurement of liquid, gas or steam
● High temperature resistance, high pressure resistance and impact resistance
Technical Parameters:
Standard Nozzle | |
Medio aplicable | Steam with high temperature or high pressure, water, liquid, gas |
Diámetro nominal | DN50 ~ DN500 |
Working pressure | ≤ 42 Mpa |
Working temperature | -50 ~ 650℃ |
Pressure tapping | Angle tapping |
Montaje | Flanged type, wafer type, welding type |
Executive standard | ISO 5167: GB / T2624 |
Precisión | ± 1.0% |
Meter tube material | Carbon steel, Stainless steel |
Nozzle material | SS304, SS316 |
Long Neck Nozzle |
|
Medio aplicable | Steam with high temperature or high pressure, water, liquid, gas |
Diámetro nominal | DN50 ~ DN500 |
Working pressure | ≤ 42 Mpa |
Working temperature | -50 ~ 650℃ |
Pressure tapping | D-D/2 tapping |
Montaje | Flanged type, wafer type, welding type |
Executive standard | ISO 5167: GB / T2624 |
Precisión | ± 2.0% |
Meter tube material | Carbon steel, Stainless steel |
Nozzle material | SS304, SS316 |
Installation and Using
1) Avoid the process pressure becoming negative pressure.
2) Prevent the nozzle’s flow field from the large motor, transformer.
3) Select the installation position which has no or slight vibration.
4) The location shall be easy grounding for the flow sensor.
5) Avoid the direct sunlight.
6) Avoid the environment where there is high concentrations of corrosive gas.
7) The requirement to the upstream / downstream straight pipe length specified in the calculation sheet shall be met.
8) The flow sensor can be installed on horizontal pipe, vertical pipe or inclined pipe, but the pipeline must be fully filled with the fluid.
9) The upstream / downstream straight pipe must be circular, the inner wall of pipeline shall be clean, no pits and deposit substance.
10) The installation of pressure tapping tube shall be comply with the industry standard.
11) Installation diagram of nozzle flow sensor for gas fluid and steam fluid as follow:
Diagram of straight pipe length at upstream / downstream:
Productos relacionados
-
Instrumento de flujo
Caudalímetro ultrasónico Doppler portátil ( Sensor de caudal con pinza )
Rated 0 de 5Seguir leyendo
PREGUNTAS FRECUENTES
Answer : Envíe su pregunta o consulta a nuestro correo electrónico: sales@hginstrument.com, remitiremos las preguntas al ingeniero correspondiente.
Answer : Por favor comuníquese con el departamento de ventas sobre el procedimiento de devolución antes de devolver el producto.
Answer : El plazo de entrega depende de la cantidad del pedido y de la especificación del producto. Si la especificación del producto es convencional ( no especial ), El plazo de entrega es de 5 ó 7 días laborables para cantidad del pedido ≤ 10 piezas; El plazo de entrega es de 2 ó 3 semanas laborables para cantidad del pedido 15 ~ 30 piezas.
Answer por correo, por mar o por aire
Answer : Sí, generalmente la garantía es de un año.