Pengukur Aliran Massa Coriolis HGCMF-C

HGCMF-C Coriolis Mass Flow Meter’s Features
  • Applicable to all kinds of liquids, mass flow measurement, with high accuracy
  • Applicable to liquids with high viscosity
  • Measurement and display of mass flow, density and temperature
  • Gas flow measurement has no relation with density, temperature and pressure
  • For the mixed gas of fixed components , the density value under standard condition (20 ℃, 325 kPa) can be used to do simple calculation to obtain standard volume of gas medium, no need of temperature and pressure compensation. This method is commonly used.
  • Flow sensor is Micro-bend type or Ultra-Micro bend type, size is smaller, save installation room

Deskripsi Produk

HGCMF-C Coriolis Mass Flow Meter’s Principles of Measurement

HGCMF-C Coriolis Mass Flow Meter has a pair of bend tubes. The principle is to detect Coriolis force forced a pair of tubes from inner mass flow by fluid.  A new force—Coriolis force would appear while two conditions met: (1) vibrating with normal frequency in a pair of bend tubes, (2) fluid flowing in tubes. This force was produced upon synthesis from vibrating force and flowing force by fluid in tubes. And tubes would be wresting symmetric the center line because the force forced. Two displacement sensors on sides of tubes detect the force and output electric signals. The signals regulated, mass flow directly produced.

 

Data teknis
UkuranMicro-bend type: DN8-DN300,  Ultra-Micro bend type: DN15 – DN250
FluidLiquid, Gas
Structure type and operation temperatureIntegral type: (-50 to 125) ℃
Remote type: (-50 to 200) ℃
High temperature Remote type (-50 to 300) ℃
Low temperature remote type (-150 to 125) ℃
Flow sensor typeMicro-bend type,  Ultra-Micro bend type
Flow transmitterDigital type, LCD display, Power supply option: 24VDC, 220VAC
Keluaran4-20mA,  4-20mA+HART, Pulse, RS485 (optional)
Peringkat tekanan 1.6 Mpa,  2.5 Mpa, 4.0 Mpa,  6.3Mpa, customize pressure
Akurasi0.1%,  0.2%,  0.5%
Koneksi prosesThread (for size ≤DN10),  Flange (for size ≥D15),  Tri-clamp (For size ≥D15)

 

Flow range of liquid fluid ( Unit: Kg/h )
DNFlow range
Can be measured
Flow range
of accuracy
0.1%, 0.15%
Flow range
of accuracy
0.2%
Flow range
of accuracy
0.5%
Zero point stability
88-80080-80055-80040-8000.08
1010-1000400-100070-100050-10000.1
1520-3000200-3000150-3000100-30000.2
2580-8000600-8000400-8000300-80000.6
40240-240002400-240001200-240001000-240002.4
50500-500005000-400002500-400002000-500005
80800-1200008000-1200007000-1200006000-1200008
100A1500-20000015000-20000012000-20000010000-20000015
100B1500-18000018000-18000014000-18000012000-18000018
150A5000-50000050000-50000030000-50000025000-50000050
150B5000-45000055000-45000035000-45000030000-45000042
200A10000-1000000100000-100000070000-100000050000-1000000100
200B10000-900000120000-90000090000-90000070000-900000120
25015000-1500000150000-1500000120000-150000075000-1500000150
30025000-2500000200000-2500000150000-2500000100000-2500000200
Note: A type for pressure rating≤2.5Mpa, B type for pressure rating≥4.0Mpa

 

Flow range of gas fluid ( Unit: Kg/h )

DNFlow range

Can be measured

Flow range

of accuracy

0.2%

Flow range

of accuracy

0.5%

zero point

stability

30.6-1206-1203-1200.015
84-80040-80020-8000.13
105-100050-100025-10000.13
1515-3000150-300075-30000.38
2540-8000400-8000200-80001.00
40160-320001600-32000800-320004.00
50250-500002500-500001250-500006.25
80700-1400007000-1400003500-14000017.5
1001000-20000010000-2000005000-20000025.0
1502500-50000025000-50000012500-50000062.5
2005000-100000050000-100000025000-1000000125
2507500-150000075000-150000037500-1500000188
30012500-2500000125000-250000062500-2500000313

 

Explosion-proof

● Explosion-proof classification of HGCMF C Series Mass flow meter is approved by NEPSI as follow table:

ModelExplosion-proof
Integral typeDN10 – DN80Exd (ib) II CT4 ~ T6
DN100 – DN200Exd (ib) II CT4 ~ T6
Remote sensorDN10 – DN80Ex (ib) IICT3 ~ T6
Remote sensorDN100 – DN200Exd (ib) IICT3 ~ T6
Remote Digital transmitterExd (ib) IICT6

● Temperature class table

T3T4T5T6
Medium temperature200℃135℃100℃85℃
Maximum surface temperature of instrument195℃130℃95℃80℃

● HGCMF-C Coriolis Mass Flow Meter’s earth terminal must be earthed when working.

● HGCMF-C Coriolis Mass Flow Meter is not allowed to change the electric parameters and standard model of explosion-proof parts in the sensor.

● HGCMF-C Coriolis Mass Flow Meter must power off before opening the cover in hazardous zone.

● The outside diameter of cable has type of φ8~φ8.5 and φ8.5~φ12. Please tighten the cable gland up when on-site using, and change the cable and gasket ring once they are aging or wearing out.

● Make sure that there is no gases which can erode aluminum alloy.

● Make sure that the maintenance or repair should be in safety zone without flammable gases.

 

Operation pannel of Pengukur Aliran Massa Coriolis HGCMF-C

front panel of hgcmf c coriolis mass flow meter

Key’s function description of HGCMF-C Coriolis Mass Flow Meter

PERTANYAAN YANG SERING DIAJUKAN

Answer : Silakan kirimkan pertanyaan atau pertanyaan Anda ke email kami: sales@hginstrument.com, kami akan meneruskan pertanyaan tersebut ke teknisi terkait.

Answer : Tolong berkomunikasi dengan bagian penjualan tentang prosedur pengembalian sebelum mengembalikan produk.

Answer : Waktu pengiriman tergantung pada jumlah pesanan dan spesifikasi produk. Jika spesifikasi produk adalah konvensional (tidak istimewa),  waktu pengiriman adalah 5 atau 7 hari kerja untuk jumlah pesanan ≤ 10 buah;  waktu pengiriman adalah 2 atau 3 minggu kerja untuk jumlah pesanan 15 ~ 30 potongan. 

Answer melalui Kurir, Laut atau Udara

Answer : Ya, Umumnya garansi satu tahun.

Answer : Dari tahun 2015 hingga tahun 2021, penjualan tahunan rata-rata adalah RMB 350 juta (sekitar USD 54,7 juta)