HGCMF-C Coriolis Mass Flow Meter

HGCMF-C Coriolis Mass Flow Meter’s Features
  • Applicable to all kinds of liquids, mass flow measurement, with high accuracy
  • Applicable to liquids with high viscosity
  • Measurement and display of mass flow, density and temperature
  • Gas flow measurement has no relation with density, temperature and pressure
  • For the mixed gas of fixed components , the density value under standard condition (20 ℃, 325 kPa) can be used to do simple calculation to obtain standard volume of gas medium, no need of temperature and pressure compensation. This method is commonly used.
  • Flow sensor is Micro-bend type or Ultra-Micro bend type, size is smaller, save installation room

Product Description

HGCMF-C Coriolis Mass Flow Meter’s Principles of Measurement

HGCMF-C Coriolis Mass Flow Meter has a pair of bend tubes. The principle is to detect Coriolis force forced a pair of tubes from inner mass flow by fluid.  A new force—Coriolis force would appear while two conditions met: (1) vibrating with normal frequency in a pair of bend tubes, (2) fluid flowing in tubes. This force was produced upon synthesis from vibrating force and flowing force by fluid in tubes. And tubes would be wresting symmetric the center line because the force forced. Two displacement sensors on sides of tubes detect the force and output electric signals. The signals regulated, mass flow directly produced.

 

Technical data
Size Micro-bend type: DN8-DN300,  Ultra-Micro bend type: DN15 – DN250
Fluid Liquid, Gas
Structure type and operation temperature Integral type: (-50 to 125) ℃
Remote type: (-50 to 200) ℃
High temperature Remote type (-50 to 300) ℃
Low temperature remote type (-150 to 125) ℃
Flow sensor type Micro-bend type,  Ultra-Micro bend type
Flow transmitter Digital type, LCD display, Power supply option: 24VDC, 220VAC
Output 4-20mA,  4-20mA+HART, Pulse, RS485 (optional)
Pressure rating  1.6 Mpa,  2.5 Mpa, 4.0 Mpa,  6.3Mpa, customize pressure
Accuracy 0.1%,  0.2%,  0.5%
Process connection Thread (for size ≤DN10),  Flange (for size ≥D15),  Tri-clamp (For size ≥D15)

 

Flow range of liquid fluid ( Unit: Kg/h )
DN Flow range
Can be measured
Flow range
of accuracy
0.1%, 0.15%
Flow range
of accuracy
0.2%
Flow range
of accuracy
0.5%
Zero point stability
8 8-800 80-800 55-800 40-800 0.08
10 10-1000 400-1000 70-1000 50-1000 0.1
15 20-3000 200-3000 150-3000 100-3000 0.2
25 80-8000 600-8000 400-8000 300-8000 0.6
40 240-24000 2400-24000 1200-24000 1000-24000 2.4
50 500-50000 5000-40000 2500-40000 2000-50000 5
80 800-120000 8000-120000 7000-120000 6000-120000 8
100A 1500-200000 15000-200000 12000-200000 10000-200000 15
100B 1500-180000 18000-180000 14000-180000 12000-180000 18
150A 5000-500000 50000-500000 30000-500000 25000-500000 50
150B 5000-450000 55000-450000 35000-450000 30000-450000 42
200A 10000-1000000 100000-1000000 70000-1000000 50000-1000000 100
200B 10000-900000 120000-900000 90000-900000 70000-900000 120
250 15000-1500000 150000-1500000 120000-1500000 75000-1500000 150
300 25000-2500000 200000-2500000 150000-2500000 100000-2500000 200
Note: A type for pressure rating≤2.5Mpa, B type for pressure rating≥4.0Mpa

 

Flow range of gas fluid ( Unit: Kg/h )

DN Flow range

Can be measured

Flow range

of accuracy

0.2%

Flow range

of accuracy

0.5%

zero point

stability

3 0.6-120 6-120 3-120 0.015
8 4-800 40-800 20-800 0.13
10 5-1000 50-1000 25-1000 0.13
15 15-3000 150-3000 75-3000 0.38
25 40-8000 400-8000 200-8000 1.00
40 160-32000 1600-32000 800-32000 4.00
50 250-50000 2500-50000 1250-50000 6.25
80 700-140000 7000-140000 3500-140000 17.5
100 1000-200000 10000-200000 5000-200000 25.0
150 2500-500000 25000-500000 12500-500000 62.5
200 5000-1000000 50000-1000000 25000-1000000 125
250 7500-1500000 75000-1500000 37500-1500000 188
300 12500-2500000 125000-2500000 62500-2500000 313

 

Explosion-proof

● Explosion-proof classification of HGCMF C Series Mass flow meter is approved by NEPSI as follow table:

Model Explosion-proof
Integral type DN10 – DN80 Exd (ib) II CT4 ~ T6
DN100 – DN200 Exd (ib) II CT4 ~ T6
Remote sensor DN10 – DN80 Ex (ib) IICT3 ~ T6
Remote sensor DN100 – DN200 Exd (ib) IICT3 ~ T6
Remote Digital transmitter Exd (ib) IICT6

● Temperature class table

T3 T4 T5 T6
Medium temperature 200℃ 135℃ 100℃ 85℃
Maximum surface temperature of instrument 195℃ 130℃ 95℃ 80℃

● HGCMF-C Coriolis Mass Flow Meter’s earth terminal must be earthed when working.

● HGCMF-C Coriolis Mass Flow Meter is not allowed to change the electric parameters and standard model of explosion-proof parts in the sensor.

● HGCMF-C Coriolis Mass Flow Meter must power off before opening the cover in hazardous zone.

● The outside diameter of cable has type of φ8~φ8.5 and φ8.5~φ12. Please tighten the cable gland up when on-site using, and change the cable and gasket ring once they are aging or wearing out.

● Make sure that there is no gases which can erode aluminum alloy.

● Make sure that the maintenance or repair should be in safety zone without flammable gases.

 

Operation pannel of HGCMF-C Coriolis Mass Flow Meter

front panel of hgcmf c coriolis mass flow meter

Key’s function description of HGCMF-C Coriolis Mass Flow Meter

FAQ

Answer : Please send your question or enquiry to our email: sales@hginstrument.com, we will forward the questions to the related engineer.

Answer :  Please communicate with the sales about the return procedure before returning product.

Answer :  The delivery time depends on the order quantity and product specification.  If the product’s specification is conventional ( not special ),  delivery time is 5 or 7 working days for order quantity ≤ 10 pieces;  delivery time is 2 or 3 working weeks for order quantity 15 ~ 30 pieces. 

Answer :  by Courier,  by Sea or by Air

Answer :  Yes,  Generally warranty is one year.

Answer :  From year 2015  to year 2021,  average annual sales is RMB 350 million ( about USD 54.7 million )

Scroll to Top