Débitmètre électromagnétique HGD ( Nouveau modèle : SY-LDY )

Débitmètre électromagnétique HGD is mainly used to measure the volume flow of water, waste water, sewage, beverage, pulp, slurry, the fluid temperature usually not more than 120℃, fluid’s conductivity not less than 5μS/cm. HGD Electromagnetic Flow Meter’s standard configuration has grounding electode. HGD Electromagnetic Flow Meter’s option communication: RS485, HART, Profibus DP, profibus PA.

HGD Electromagnetic Flow Meter is widely used in oil and gas field water injection, sewage treatment, paper making, municipal water supply and drainage.
Tags chauds : À propos du groupe Suyi,Instrument de mesure du débit,Transmetteur de niveau,débitmètre d'eau

Description du produit

Common used type​ of HGD Electromagnetic Flow Meter
In-line compact type
External powered
In-line Remote type
External powered
In-line compact type
Battery powered
In-line Remote type
Battery powered
emf t1emf t2w803e f3emf t4

 

Technical data of HGD Electromagnetic Flow Meter
Suitable DiameterDN10~DN2600 (below DN25 non-standard)
Electrode quantity3pcs ( a pair of measuring electrode and a ground electrode)
Suitable FluidLiquid with conductivity not less than 5 μs/cm
Measuring Range0.5~10m/s (extendable to 15m/s)
Upper Limit of Span0.5~10m/s. 1~5m/s recommended
Précision0.5%, 1.0% of F.S.
RépétabilitéBetter than 0.25%
Display of ConverterDisplay : Flow rate ( 4-digits), Totalizer (9-digits), Velocity, Alarm status by LCD ( LED-option)
Flow unit: L/h, L/m, L/s, m3/h, m3/min, m3/s,
USG/h, USG/min,USG/s ( USG is us Gallon on request )
Flow direction : selectable by program
3 Digits display below of decimal points.
K-factor: 5 digits.
Programming language: English, Chinese
Structure option: Compact type; Remote Type
Power supply option85 ~ 250VAC / 50 or 60Hz; 20 ~ 36VDC,  Battery power: 3.6V lithium battery
Output Signal4~20m ADC, load ≤ 750ohm,
0~3kHz, 5V with source and changeable width.High terminal and effective frequency output
Voltage output:0-5 V DC
Conduit connectionThread M20 * 1.5
Communication optionRS-485; HART
Operation Pressure1.0MPa, 1.6MPa, 4.0MPa, 16MPa (Special)
Température de fonctionnementDepends on liner material
Ambient TemperatureSensor -40°C ~80°C. transducer -10°C ~50°C
Ambient Humidity≤ 85%RH (at 20 ℃)
Power Consumption≤ 8W
Wheather-proofCompact type: IP65. Remote type: sensor IP68, transducer IP65.
Electrode material option316L (stainless steel), Hastelloy C, Hastelloy B, Titanium, Tantalum
Liner material optionPTFE, Soft rubber, Hard rubber, F46, FS, PUR.
Meter tube material optionCarbon steel, SS304
Type de connexionFlange connection, Tri-clamp
Flange standard optionGB9119-88 (DIN2051, BS4504), JIS, ANSI
AntidéflagrantExd mb IICT6 Gb
CertificatISO9001:2015, ISO14001:2015, SIL 3, OHSAS18001:2007

 

Dimension for DN15~DN150 Compact type HGD Electromagnetic Flow Meter

drawing of in line type

DNLHEstimated weight (Kg)
Integral meterSensor
15200220107
20200220129
252002301411
322002351512
402002451613
502002501714
652002702522
802002852926
1002503003128
1252503303532
1503003604138

 

Wiring Terminal instruction of  HGD Electromagnetic Flow Meter’s remote converter as follow table:

Wiring TerminalDescriptionRemarque
SIG1Signal lPour les transducteurs à distance
SGNDMasse du signal
SIG2Signal 2
DS1Blindé Excitant 1
DS2Blindé Excitant 2
EXT +Un courant "+" passionnant
EXT -Un courant passionnant "-"
VDIN24VDC Point de connexion (pour une sortie de courant à 2 fils)A utiliser pour le câblage de la sortie analogique de courant
IOUTSortie analogique de courant
ICOMSortie courant analogique Masse
POUTFréquence de débit (impulsion) SortieA utiliser pour le câblage de la fréquence (impulsion) Sortie
PCOMFréquence (impulsion) Sortie Masse
ALMHSortie d'alarme de limite supérieureA utiliser pour le câblage de l'alarme Sortie
ALMLSortie d'alarme de limite inférieure
ACOMSortie d'alarme Terre
TRX+Terminal de communication (RS485 A+)Utilisation pour le câblage de communication
TRX-Terminal de communication (RS485 B-)
TCOMMasse de la communication RS232
LConnecter 220VAC / 24VDC +
NConnecter 220VAC / 24VDC -

 

Wiring Terminal instruction of  HGD Electromagnetic Flow Meter’s compact converter as follow table:

Wiring TerminalDescriptionRemarque
L 2Connecter 220VAC / 24VDC -
L 1Connecter 220VAC / 24VDC +
COMSortie de courant à la terre pour la mesure du débitA utiliser pour le câblage de la sortie analogique de courant
I +Sortie de courant pour la mesure du débit
COMFréquence / Sortie d'impulsion MasseUtilisation pour le câblage de la fréquence / de l'impulsion Sortie
P+Sortie fréquence / impulsion pour débit bidirectionnel
AHSortie d'alarme pour la limite supérieureA utiliser pour le câblage de l'alarme Sortie
ALSortie d'alarme pour la limite inférieure
COMMasse de la sortie d'alarme (connecter avec la masse de la sortie de courant ou la masse de la sortie de fréquence / d'impulsion)
FUSEFusible pour l'alimentation électrique
T +Terminal de communication (RS485 A+)Utilisation pour le câblage de communication
GMasse de la communication RS232
T -Terminal de communication (RS485 B-)

 

HGD Electromagnetic Flow Meter’s converter has 54 parameters totally,  user can operate buttons to set parameters, HGD Electromagnetic Flow Meter’s parameter list is shown as following table:

ObjetParameter wordsFunction descriptionSetting wayGammePassword Grade
1LanguageDisplay languageSelectChinese / English2
2Comm AddresInstrument Communication AddressSetting Value0 ~ 992
3Baud RateInstrument Communication SpeedSelect300 ~ 384002
4Snsr SizePipe line SizeSelect3 ~ 30002
5Flow UnitMeasuring UnitSelectL/h, L/m, L/s, m3/h  m3/min,m3/s2
6Flow RangeMeasure range SettingSetting Value0 ~ 999992
7Flow RspnsMeasure Damping TimeSelect1 ~ 502
8Flow DirectMeasuring Direction SelectionSelectForward / Reverse2
9Flow ZeroFlow Zero AmendmentSetting Value0 ~ ±99992
10Flow CutoffSmall Signal Resection PointSetting Value0 ~ 599.99%2
11Cutoff EnaResection Point Indication

Permission

SelectPermit /Prohibit2
12Total UnitFlow Totalize UnitSelect0.001m3 ~ 1 m3

0.001 L ~ 1 L

2
13SegmaN EnaReverse Output PermissionSelectPermit /Prohibit2
14Analog TypeCurrent Output TypeSelect0 ~ 10 mA / 4 ~ 20mA2
15Pulse TypePulse Output ModeSelectFrequency/Pulse2
16Pulse FactPulse

Unit equivalent

Select0.001m3 ~ 1 m3

0.001 L ~ 1 L

2
17Freque MaxFrequency Output RangeSelect1 ~ 5999 Hz2
18Mtsnsr EnaEmpty pipe Alarm PermissionSelectPermit/Prohibit2
19Mtsnsr TripEmpty pipe Alarm ThresholdSetting Value59999%2
20Alm Hi EnaUpper Limit Alarm PermissionSelectPermit/Prohibit2
21Alm Hi ValUpper Limit Alarm ValueSetting Value000.0 ~ 599.99%2
22Alm Lo EnaLower Limit Alarm PermissionSelectPermit/Prohibit2
23Alm Lo ValLower Limit Alarm ValueSetting Value000.0 ~ 599.99%2
24Sys Alm EnaExcitation Alarm PermissionSelectPermit/Prohibit2
25Clr Sum KeyTotal Flow Zero PasswordSetting Value0 ~ 999993
26Snsr Code1Sensor Code 1User SettingFactory Year Month (0 ~ 99999)4
27Snsr Code2Sensor Code 2User SettingProduct Serial No ( 0 ~ 99999)4
28Field TypeExciting frequency typeSelectType 1, 2, 34
29Sensor FactSensor Factor ValueSetting Value0.0000 ~ 5.99994
30Total PointBatch control volume setSetting Value00000~599994
31Line CRC EnaFlow amend permissionSelectPermit/Prohibit5
32Lineary CRC1Flow amend point 1User Settingsetting according to the velocity5
33Lineary Fact 1Flow amend value 1User Setting0.0000~1.99995
34Lineary CRC2Flow amend point 2User Settingsetting according to the velocity5
35Lineary Fact 2Flow amend value 2User Setting0.0000~1.99995
36Lineary CRC3Flow amend point 3User Settingsetting according to the velocity5
37Lineary Fact 3Flow amend value 3User Setting0.0000~1.99995
38Lineary CRC4Flow amend point 4User Settingsetting according to the velocity5
39Lineary Fact4Flow amend value 4User Setting0.0000~1.99995
40FwdTotal LoForward Total Flow Low LevelRevisable00000 ~ 999995
41FwdTotal HiForward Total Flow High LevelRevisable0000 ~ 99995
42RevTotal LoReverse Total Flow Low LevelRevisable00000 ~ 999995
43RevTotal HiReverse Total Flow High LevelRevisable0000 ~ 99995
44PlsntLmtEnaPeak Restriction PermissionSelectPermit/Prohibit5
45PlsntLmtValPeak Restriction FactorSelect0.010 ~ 0.800 m/s5
46Plsnt DelayPeak Restriction TimeSelect400 ~ 2500 ms5
47Pass Word 1Password grade 1Use Revisable00000 ~ 999995
48Pass Word 2Password grade 2Use Revisable00000 ~ 999995
49Pass Word 3Password grade 3Use Revisable00000 ~ 999995
50Pass Word 4Password grade 4Use Revisable00000 ~ 999995
51Analog ZeroCurrent Zero AmendmentSetting Value0.0000 ~ 1.99995
52Anlg RangeCurrent Full Span AmendmentSetting Value0.0000 ~ 3.99995
53Meter FactCalibration FactorSetting Value0.0000 ~ 5.99995
54MeterCode 1Instrument Code 1Factory SettingFactory Year Month (0 ~ 99999)6
55MeterCode 2Instrument Code 2Factory SettingProduct Serial No. (0~99999)6

 

 

Atelier Ligne d'assemblage
   chaîne de montage d'ateliers

 

Atelier Ligne d'étalonnage

 

Entrepôt

entrepôt

 

Filed application of HGD Electromagnetic Flow Meter

Drink water flow measurement                                                                                           Waste water flow measurement                                            Slurry flow measurement

field application

Electromagnetic Flow Meter–An Ultimate FAQ Guide:

1. What is an Electromagnetic Flow Meter?
An Electromagnetic Flow Meter (EMF) is a type of flow meter that measures the velocity of conductive fluids through a pipe by using a magnetic field.

2. How does an Electromagnetic Flow Meter work?
An Electromagnetic Flow Meter works by applying a magnetic field perpendicular to the direction of fluid flow. As the conductive fluid passes through the magnetic field, a voltage is generated which is proportional to the flow velocity.

3. What types of fluids can an Electromagnetic Flow Meter measure?
Electromagnetic Flow Meters can measure the flow rate of conductive fluids, such as water, chemicals, sewage, and slurries.

4. Is an Electromagnetic Flow Meter accurate?
Yes, Electromagnetic Flow Meters are highly accurate and can achieve a measurement accuracy of +/- 0.5%.

5. What is the measuring range of an Electromagnetic Flow Meter?
The measuring range of an Electromagnetic Flow Meter varies depending on the size and type of the meter, but it can range from 0.01 m/s to 10 m/s.

6. Can an Electromagnetic Flow Meter be used for both liquid and gas flow measurement?
No, Electromagnetic Flow Meters can only be used for measuring the flow of conductive liquids.

7. Can an Electromagnetic Flow Meter be installed in any orientation?
No, Electromagnetic Flow Meters must be installed horizontally with the flow direction being a straight line to achieve accurate measurements.

8. Do Electromagnetic Flow Meters require regular calibration?
Yes, it is recommended to calibrate an Electromagnetic Flow Meter annually to ensure accuracy.

9. Can an Electromagnetic Flow Meter withstand high temperatures and pressures?
Yes, most Electromagnetic Flow Meters can operate at temperatures up to 200°C and pressures up to 16 bar.

10. What is the lifespan of an Electromagnetic Flow Meter?
The lifespan of an Electromagnetic Flow Meter can vary depending on usage and maintenance, but they can typically last for more than 10 years.

11. Are there any special installation requirements for an Electromagnetic Flow Meter?
Yes, it is important to have a straight pipe section both upstream and downstream of the Flow Meter to ensure accurate readings.

12. Can an Electromagnetic Flow Meter be used for measuring pulsating flow?
Yes, some Electromagnetic Flow Meters have the capability to measure pulsating flow, but it is important to check the specifications of the meter.

13. What are the advantages of an Electromagnetic Flow Meter compared to other flow meters?
Some advantages of an Electromagnetic Flow Meter include its accuracy, non-intrusive installation, and low maintenance requirements.

14. Is it possible to have multiple outputs with an Electromagnetic Flow Meter?
Yes, most Electromagnetic Flow Meters have the capability to provide multiple outputs, including 4-20 mA, 0-10 V, and digital communication options.

15. Can an Electromagnetic Flow Meter be used in hazardous environments?
Yes, there are options for explosion-proof and intrinsically safe Electromagnetic Flow Meters that can be used in hazardous environments. However, it is important to check the specifications and certifications of the meter.

FAQ

ARéponse : Veuillez envoyer votre question ou votre demande à notre adresse électronique : sales@hginstrument.com, nous transmettrons les questions à l'ingénieur concerné.

ARéponse : S'il vous plaît communiquer avec le service des ventes au sujet de la procédure de retour avant de renvoyer le produit.

ARéponse : Le délai de livraison dépend de la quantité commandée et des spécifications du produit. Si la spécification du produit est conventionnel ( pas spécial ),  Le délai de livraison est de 5 ou 7 jours ouvrables pour quantité commandée ≤ 10 pièces ;  Le délai de livraison est de 2 à 3 semaines ouvrables pour les quantité de commande 15 ~ 30 pièces. 

ARéponse par courrier, par mer ou par air

ARéponse : Oui, la garantie est généralement d'un an.

ARéponse : De 2015 à 2021, les ventes annuelles moyennes s'élèvent à 350 millions RMB (environ 54,7 millions USD).