HGLS-2000B Débitmètre ultrasonique mural
HGLS-2000B wall-mount ultrasonic flow meter is designed to be installed in a fixed location for long-term flow measuring. Features as follow:
● Principle: transit-time measuring, Weather proof: IP67
● Measurable flow velocity: 0.03 – 7m/s, Accuracy: better than 1% for flow
● LCD screen, display total flow / heat, instant flow / heat, velocity, time etc.
● Output option: 4-20mA / OCT pulse,RS485, Modbus protocol (standard config.), Relay alarm (optional)
● Pt100 resistor input (optional, for heat measuring)
● Power supply option: 24VDC, 220VAC
● Signal Cable length: 5m * 2 (standard config.), or customize cable length
● Guide rail mounting ( Optional )
Description du produit
Technical Specifications
| Objet | description | |
| Main unit | Précision | Better than ± 1% |
| Répétabilité | Better than 0.2% | |
| Principe | Transit-time measuring principle | |
| Measurement period | 500ms | |
| Affichage | LCD with backlight , display accumulated flow/heat, instantaneous Flow / heat, velocity, time etc. |
|
| Sortie | Analogue output: 4-20mA or 0-20mA current output. Impedance 0 -1k Ω. Accuracy 0.1%. | |
| OCT output: Frequency signal (1~9999HZ) | ||
| Relay output: over 20 source signal (no signal, reverse flow etc.) | ||
| RS485 serial port | ||
| Input | Three analogue input | |
| Three-wire PT100 resistor input (optional) | ||
| Other functions | Automatically record t he totalizer data of the last 64 days / 64 months /5 years. The power-on time and corresponding flow rate of the last 64 power on and off events. Allow manual or automatic flow loss compensation. The instrument working status of the last 64 days. | |
| Pipe | Matériau | Steel, stainless steel, cast iron, cement pipe, copper, PVC, aluminum, FRP etc. Liner is allowed |
| Taille | DN 32 -6000mm | |
| Straight pipe section |
Upstream ≥10D, Downstream ≥ 5D, distance from the pump discharge ≥ 30D. (D stands for pipe diameter) | |
| Fluide (must fully fill the pipeline ) |
Type | Liquid, no strong corrosivity, Common used fluid: Water, sea water, sewage, alcohol, beer. |
| Température | Standard: -30 ˚ C – 90 ˚ C , High-temperature : -30 ˚ C – 160 ˚ C | |
| Flow velocity measurable range | 0 .03 ~ 7 m/s | |
| Turbidity | Content of particulate impurity and bubbles shall be less than 10000ppm. | |
| Flow Direction | Bi-directional measuring, net flow/heat measuring | |
| Environment | Température | Main Unit: -30 ˚ C – 80 ˚ C |
| Transducer: -40 ℃-160 ℃, Temperature transducer: select on enquiry | ||
| Humidity | Main Unit: 85% RH | |
| Transducer: water-immersible, water depth less than 3m | ||
| Cable | Twisted Pair Line, standard length of 10m, can be extended to 500m (but such length is not recommended); contact the manufacturer for longer cable if requirement. RS-485 interface, transmission distance up to 1000m |
|
| Power Supply | AC220V or DC24V | |
| Power consumption | Less than 1.5W | |
| Protocols | MODBUS, M-BUS, Fuji extended protocol and other factory protocol | |
| Optional configuration | SD card, capacity 2G, storage time depends on storage interval setting. | |
Application diagram
| Sensor type | Flow measure | Flow measure and Heat measure | Features |
| Clamp-on type |
![]() |
![]() |
1>. Not need stop process when installation |
| Insertion type |
![]() |
![]() |
1>. Not need stop process when installation 2>. Stable and reliable 3>. Can be equipped with insertion type temperature sensor to measure heat |
| On-line type | ![]() |
![]() |
1>. Not need stop process when installation |
Optional Flow Sensor
| Sensor appearance | code | Description | Température | Précision |
![]() |
TS-2 | Small size clamp-on type (Magnetic) for DN15~DN100mm |
-30℃~90℃ | ±1%FS |
![]() |
TM-1 | Middle size clamp-on type (Magnetic) for DN50~DN700mm |
-30℃~90℃ | ±1%FS |
![]() |
TL-1 | Large size clamp-on type (Magnetic) for DN300~DN6000mm |
-30℃~90℃ | ±1%FS |
![]() |
TS-2-HT | Small size High-temperature clamp-on type for DN15~DN100mm |
-30℃~160℃ | ±1%FS |
![]() |
TM-1-HT | Middle size High-temperature clamp-on type for DN50~DN700mm |
-30℃~160℃ | ±1%FS |
![]() |
TL-1-HT | Large size High-temperature clamp-on type for DN300~DN6000mm |
-30℃~160℃ | ±1%FS |
![]() |
TC-1 | Standard Insertion type For pipeline wall thickness ≤20 mm |
-30℃~160℃ | ±2~ 3%FS |
![]() |
TC-2 | Extended Insertion type For pipeline wall thickness ≤70 mm |
-30℃~160℃ | ±2~ 3%FS |
![]() |
TC-3 | Parallel Insertion type No requirement to the pipeline wall thickness, be suitable “V” method mounting |
-30℃~160℃ | ±3~ 5%FS |
![]() |
G3 | ‘π’ shape tube transducer for DN15~DN32mm |
-30℃~160℃ | ±0.5%FS |
![]() |
G1 | Standard tube transducer for DN40~DN6000mm |
-30℃~160℃ | ±0.5%FS |
Feild Installation
Produits apparentés
-
Instrument de mesure du débit
HGLS-2000P Débitmètre portable à ultrasons
Rated 0 out of 5En savoir plus -
Instrument de mesure du débit
HGLS-2000UF Débitmètre à ultrasons en ligne
Rated 0 out of 5En savoir plus
FAQ
ARéponse : Veuillez envoyer votre question ou votre demande à notre adresse électronique : sales@hginstrument.com, nous transmettrons les questions à l'ingénieur concerné.
ARéponse : S'il vous plaît communiquer avec le service des ventes au sujet de la procédure de retour avant de renvoyer le produit.
ARéponse : Le délai de livraison dépend de la quantité commandée et des spécifications du produit. Si la spécification du produit est conventionnel ( pas spécial ), Le délai de livraison est de 5 ou 7 jours ouvrables pour quantité commandée ≤ 10 pièces ; Le délai de livraison est de 2 à 3 semaines ouvrables pour les quantité de commande 15 ~ 30 pièces.
ARéponse par courrier, par mer ou par air
ARéponse : Oui, la garantie est généralement d'un an.
ARéponse : De 2015 à 2021, les ventes annuelles moyennes s'élèvent à 350 millions RMB (environ 54,7 millions USD).