HGUOC Débitmètre à ultrasons à canal ouvert
HGUOC Ultrasonic Open channel flow meter contain main unit and sensor, connect sensor to main unit through cable. Sensor detect the liquid level in weir or flume base on the principle of sound wave reflection, then main unit use the related formula to calculate the liquid volume flow which pass weir or flume.
Ultrasonic Open channel flow meter is non-contact instrument, widely service groundwater flow monitoring system, Industrial wastewater discharge monitoring, accurately measuring open channel flow.
Description du produit
Advantage:
- Non-contact measuring, sensor does not contact the measured medium, without hazard of abrasion and corrosion, long span and easy to maintain
- High accuracy, liquid level change 1mm, the volume flow will also change correspondingly
- Suitable for many weir/flume, support international and ISO version of weir/groove, such as Parshall flume, triangular weir (30°, 45°, 60°, 90°, 120°), rectangular weir(can customize weir’s width),can input formula of calculating volume flow.
- LCD display with backlight, operation language option: Chinese / English
- Can set flow unit, correct accumulated flow and set many menu item
- Simple to programming, easy to operate
- Sensor weather proof grade: IP68
- Sensor has strong anti-interference performance, low blind area, high sensitivity, the length of cable connecting sensor to main unit can reach to 1000m
- Can supply 6 relay outputs, pulse output of accumulated flow
- Can supply RS485 communication base on Modbus-RTU protocol
- Can supply corresponding manipulator for operate expediently
- Can customize solar power supply mode, wireless transmission(database server is in China)
Principe:
Ultra sensor is installed on the top of weir/flume( shown as diagram above), sensor emit a bunch of sound wave to liquid surface periodically, when this bunch of wave reach to liquid surface, it will be reflected back and received by sensor, main unit will measure the transmission time (t) of this process. The known sound wave velocity is “V”. d=V*t/2, h=H-d
For the known weir/flume, there is a certain function relationship between the volume flow and the corresponding liquid level value. That is Q= f (h). In main unit, you can set parameter value of weir/flume according to the known weir/flume, the main unit will calculate volume flow automatically during measuring process. Ultrasonic open channel flow meter firstly measures the distance from sensor to the liquid surface, then calculate the liquid level value, then calculate the volume flow. It is important for Installation and commissioning to know this flow meter’s working principle.
Main unit technical data:
Main unit parameter description | |
Weir/flume type | ISO type: Parshall flume (No.1 to 23), rectangular weir(25/50/75/100cm or customize weir width), triangular weir(30°, 45°, 60°, 90°, 120°), customized weir/flume China National type: Parshall flume (No.1 to 25), rectangular weir (25/50/75/100cm or customize weir width), Right-angled triangle weir, customized weir/flume. |
Level resolution | 1 mm |
Level error | 1mm or 0.2%FS @ stable condition |
Affichage | LCD display with graph and backlight |
Op. Language | Chinese / English (can be selected) |
Parameter setting | Keys operation ( manipulator is option) |
Instant flow display range | 0.000 – 999999L/S or m3/h, m3/min (automatically conversion base on selected flow unit) |
Total flow display Max. value | 99999999.9 m3/h |
Analog output | 4-20mA (corresponding to instant flow) |
Load resistance | 0-500Ω |
Communication | RS485 interface, Modbus-RTU protocol |
Sortie relais | Upper limit/lower limit alarm (to control instant flow or liquid level) Pulse output (for accumulated flow, pulse equivalent can be selected) |
Relay switch mode | Normal open / Normal close (can select) |
Relay Number | 6 pcs at most |
Relay specification | 5A 250VAC / 30VDC |
Alimentation électrique | 24VDC (±5%) 0.2A; 220VAC(±20%) 0.1A |
Cycle de mesure | 1 second as default (can set) |
Temp. ambiante | -40 to 75℃ |
Matériau du boîtier | ABS |
Résistant aux intempéries | IP67 |
Cable gland | PG9 / PG11 / PG13.5 |
Montage | Wall mounted |
Taille | 250*185*125 mm |
Sensor technical data:
Sensor parameter description |
|
Level Range | 0.00 ~ 4.00 m, 6.00m, 8.00m, 12.00m, 20.00m, 30.00m, 40.00m |
Blind area | 0.20m |
Operation Temp. | -40 to 70℃ |
Résistant aux intempéries | IP68 |
Shell material | Option: ABS / PVC / PTFE |
Pression nominale | 0.2 Mpa |
Longueur du câble | Standard configure: 10m, (can extend to 1000m) |
Beam angle | 8°(3db) |
Montage | Thread, Flanged, Bracket |
Schéma d'installation :
Produits apparentés
-
Instrument de mesure du débit
Débitmètre électromagnétique à insertion HGCD
Rated 0 out of 5En savoir plus
FAQ
ARéponse : Veuillez envoyer votre question ou votre demande à notre adresse électronique : sales@hginstrument.com, nous transmettrons les questions à l'ingénieur concerné.
ARéponse : S'il vous plaît communiquer avec le service des ventes au sujet de la procédure de retour avant de renvoyer le produit.
ARéponse : Le délai de livraison dépend de la quantité commandée et des spécifications du produit. Si la spécification du produit est conventionnel ( pas spécial ), Le délai de livraison est de 5 ou 7 jours ouvrables pour quantité commandée ≤ 10 pièces ; Le délai de livraison est de 2 à 3 semaines ouvrables pour les quantité de commande 15 ~ 30 pièces.
ARéponse par courrier, par mer ou par air
ARéponse : Oui, la garantie est généralement d'un an.
ARéponse : De 2015 à 2021, les ventes annuelles moyennes s'élèvent à 350 millions RMB (environ 54,7 millions USD).