Medidor de caudal eletromagnético alimentado por bateria

Battery powered Electromagnetic flow meter is mainly used on the sites which have no external power supply, to measure the volume flow of water, waste water, sewage, beverage, slurry, the fluid temperature usually not more than 120℃, fluid’s conductivity not less than 5μS/cm.

Standard configuration of Battery Powered Electromagnetic Flow Meter: Lithium battery powered (3.6V / 19AH),  can support flow meter continuously working for about 5 years.
Hot Tags: Sobre o Grupo Suyi,Instrumento de caudal,Transmissor de nível,medidor de caudal de água

Descrição do produto

Introduction to Battery Powered Electromagnetic Flow Meter’s W803E display pannel

 

w803e c2

 

Infrared remote controller for operating on W803E display panel of Battery Powered Electromagnetic Flow Meter

 

infrared controller

 

Technical data of Battery Powered Electromagnetic Flow Meter
Suitable DiameterDN25~DN2600 (below DN25 non-standard)
Electrode quantity3pcs ( a pair of measuring electrode and a ground electrode)
Suitable FluidLiquid with conductivity not less than 5 μs/cm
Measuring Range0.5~10m/s (extendable to 15m/s)
Upper Limit of Span0.5~10m/s. 1~5m/s recommended
Exatidão0.5%, 1.0% of F.S.
RepetibilidadeBetter than 0.25%
Display of ConverterDisplay : Flow rate ( 4-digits), Totalizer (9-digits), Velocity, Alarm status by LCD ( LED-option)
Flow unit: L/h, L/m, L/s, m3/h, m3/min, m3/s,
USG/h, USG/min,USG/s ( USG is us Gallon on request )
Flow direction : selectable by program
3 Digits display below of decimal points.
K-factor: 5 digits.
Programming language: English, Chinese
Structure option: Compact type; Remote Type
Power supply configurationLithium battery pack, 3.6V/19AH (only support flow meter exciting and display, not support analog output or communication)
Função opcionalExternal powered 12VDC / 24VDC, RS485 communication
Operation Pressure1.0MPa, 1.6MPa, 4.0MPa, 16MPa (Special)
Temperatura de funcionamentoDepends on liner material
Temperatura ambienteSensor -40°C ~80°C. transducer -10°C ~50°C
Ambient Humidity≤ 85%RH (at 20 ℃)
Consumo de energia≤ 8W
Wheather-proofCompact type: IP65. Remote type: sensor IP68, transducer IP65.
Electrode material option316L (stainless steel), Hastelloy C, Hastelloy B, Titanium, Tantalum
Liner material optionPTFE, Soft rubber, Hard rubber, F46, FS, PUR.
Meter tube material optionCarbon steel, SS304
Tipo de ligaçãoFlange connection, Tri-clamp
Flange standard optionGB9119-88 (DIN2051, BS4504), JIS, ANSI
À prova de explosãoExd mb IICT6 Gb
CertificateISO9001:2015, ISO14001:2015, SIL 3, OHSAS18001:2007

 

Menu list of Battery Powered Electromagnetic Flow Meter

Menu codeMenu levelDescrição
Parameters SetLevel 1Has submenus
Clr Total RecTotal flow clearing
Flow Total RecMonth total flow record
Heat Total RecMonth heat flow record
Error RecordError record
Operate ModeLevel 2,  ( in Level 1

Menu ”Parameters Set”)

Has submenus
Flow ParametersHas submenus
Output ParameterHas submenus
Sensor ParametHas submenus
LinearizationHas submenus
Tempert Param.Has submenus
ComunicaçãoHas submenus
Date ParametersHas submenus
Factory AdjustHas submenus
Total ParameterHas submenus
Pressure Param.Has submenus
Test ParameterHas submenus
Operate ModeLevel 3,  ( in Level 2

Menu ” Operate Mode”)

Flow measure mode select setting

Option: Flow only, Flow+Pressure, Flow+Temperature

Interval TimeMeasure time interval setting
Meter DormancyMeter dormancy password setting
Measure ModeHeat measuring mode select setting
LCD off EnableLCD screen shutdown mode Enable
Sensor SizeLevel 3,  ( in Level 2

Menu ” Flow Parameters”)

Meter pipe size selection
Flow UnitFlow unit selection
Flow RangeFlow range setting
Flow DirectonFlow direction selection
Flow Zero CRCFlow zero point correct
Flow CutoffSmall flow signal cut-off setting
Flow FilterTimeMeasure damping time setting
Reverse Flow EnReverse flow measuring Enable
Starting ValueThreshold value of frequently measuring
High Alm. LimitFlow rate High limit Alarm
Heat DisplayHeat display select setting
Pulse Output EnLevel 3,  ( in Level 2

Menu ” Output Parameter”)

Pulse output Enable
Pulse UnitPulse output unit
Pulse FactorSetting Pulse equivalent
Pulse WidthSetting pulse width
Sensor FactorLevel 3, ( in Level 2

Menu ”Sensor Paramet.”)

Sensor coefficient setting
Excitation TimeExcitation Mode selection
Sensor CodingSensor Code
Empertypipe ValueThreshold of Empty pipe alarm
Emperty Zero CRCEmpty pipe zero point correct
Emperty Range CRCEmpty pipe full point correct
System Alarm EnSystem alarm Enable
Linearizati. EnaLevel 3,  ( in Level 2

Menu ” Linearization”)

Flow linearity correct Enable
Speed Point 1Flow point1
Speed Value 1Flow point1’s corrected value
Speed Point 2Flow point2
Speed Value 2Flow point2’s corrected value
Speed Point 3Flow point3
Speed Value 3Flow point3’s corrected value
Speed Point 4Flow point4
Speed Value 4Flow point4’s corrected value
Speed Point 5Flow point5
Speed Value 5Flow point5’s corrected value
Speed Point 6Flow point6
Speed Value 6Flow point6’s corrected value
Speed Point 7Flow point7
Speed Value 7Flow point7’s corrected value
Speed Point 8Flow point8
Speed Value 8Flow point8’s corrected value
Finish PointFlow velocity correct of the flow end point
Heat UnitLevel 3,  ( in Level 2

Menu ” Tempert Param.”)

Heat unit selection
Sensor PositionFlow sensor position setting
Temperat. FilterTemperature sensor filtering time selection
Ent. T Zero CRCInlet temperature zero point correcting
Ent. T Range CRCInlet temperature full span point correcting
Out. T Zero CRCOutlet temperature zero point correcting
Out. T Range CRCOutlet temperature full span point correcting
Pressure RangeBattery power supply heat meter is set at 0.6MP and 1.6MP pressures according to the

industry standard CJ128-2007 of the People’s Republic of China.

Ent. Temp. Calic.Inlet temperature correcting factor
Out. Temp. Calic.Outlet temperature correcting factor
CommAddresLevel 3,  ( in Level 2

Menu ” Communication”)

Communication address range is from 01 to 199. address 0 is reserved.
Communicat.GapCommunication Gap is used to send data to communication terminal, set range: 01~199 s.
IrDA Port EnaThis menu is temporarily reserved.
Communicat.rateBaud rate setting
Communicat.checkInstrument is no parity of standard MODBUS check mode. Users can choose odd parity or even parity as needed.
YEARLevel 3,  ( in Level 2

Menu ” Date Parameters”)

Year-time setting
MONTHMonth-time setting
DAYDay-setting
HOURHour-time setting
MINUTEMinute-time setting
SECONDSecond-time setting
LanguageLevel 3,  ( in Level 2

Menu ” Factory Adjust”)

Display language selection (Chinese / English)
Meter FactorMeter’s calibration coefficient (factory setting)
Meter CorrectMeter’s correct coefficient (factory setting)
Enter Password1Password setting (permit enter menu “parameter set”)
Meter code1Code records of the time the converter leaves the factory and the number.
Meter code2
Meter code3
Meter code4
MultiplierThis menu is temporarily reserved.
Factory LogoFactory logo Enable
Flow Total UnitLevel 3, ( in Level 2

Menu ” Total Parameter”)

Total flow integrating unit selection
Heat Total unitTotal heat integrating unit selection
Clear Total KeyPassword setting (permit total clear)
FWD Total LowLow bits of forward total flow
FWD Total HighHigh bits of forward total flow
REV Total LowLow bits of reverse total flow
REV Total HighHigh bits of reverse total flow
Heat Total LowLow bits of heat total
Heat Total HighHigh bits of heat total
Total DisplayTotal display mode selection
Pressure UnitLevel 3,  ( in Level 2

Menu ” Pressure Param”)

Pressure unit selection
P_Sensor ExcitPressure exiciting current selection
Pressure GainPressure gain setting
Pressure Zero CRCPressure zero point correcting
Press. Gain CRCPressure full point correcting
Set VelocityLevel 3,  ( in Level 2

Menu ” Test Parameter”)

This menu is temporarily reserved.
Set Ent.Tempe.This menu is temporarily reserved.
Set Exi.Tempe.This menu is temporarily reserved.

 

Oficina Linha de montagem
   linha de montagem em oficina

 

Oficina Linha de calibração

 

Armazém

armazém

 

Filed application of ElectroMagnetic flow meter

Drink water flow measurement                                 Waste water flow measurement                           Slurry flow measurement

field application

 

 

FAQ

Aresposta : Por favor, envie a sua pergunta ou inquérito para o nosso e-mail: sales@hginstrument.com, nós encaminharemos as perguntas para o engenheiro relacionado.

Aresposta : Por favor comunicar com o departamento de vendas sobre o procedimento de devolução antes de devolver o produto.

Aresposta : O prazo de entrega depende da quantidade encomendada e da especificação do produto. Se a especificação do produto for convencional ( não especial ),  o prazo de entrega é de 5 ou 7 dias úteis para quantidade da encomenda ≤ 10 peças;  o prazo de entrega é de 2 ou 3 semanas úteis para quantidade de encomenda 15 ~ 30 peças. 

Aresposta : por correio, por mar ou por ar

Aresposta : Sim, geralmente a garantia é de um ano.

Aresposta : Do ano 2015 ao ano 2021, as vendas médias anuais são de 350 milhões de RMB (cerca de 54,7 milhões de USD)