Medidor de caudal ultrassónico de canal aberto HGUOC
HGUOC Ultrasonic Open channel flow meter contain main unit and sensor, connect sensor to main unit through cable. Sensor detect the liquid level in weir or flume base on the principle of sound wave reflection, then main unit use the related formula to calculate the liquid volume flow which pass weir or flume.
Ultrasonic Open channel flow meter is non-contact instrument, widely service groundwater flow monitoring system, Industrial wastewater discharge monitoring, accurately measuring open channel flow.
Descrição do produto
Advantage:
- Non-contact measuring, sensor does not contact the measured medium, without hazard of abrasion and corrosion, long span and easy to maintain
- High accuracy, liquid level change 1mm, the volume flow will also change correspondingly
- Suitable for many weir/flume, support international and ISO version of weir/groove, such as Parshall flume, triangular weir (30°, 45°, 60°, 90°, 120°), rectangular weir(can customize weir’s width),can input formula of calculating volume flow.
- LCD display with backlight, operation language option: Chinese / English
- Can set flow unit, correct accumulated flow and set many menu item
- Simple to programming, easy to operate
- Sensor weather proof grade: IP68
- Sensor has strong anti-interference performance, low blind area, high sensitivity, the length of cable connecting sensor to main unit can reach to 1000m
- Can supply 6 relay outputs, pulse output of accumulated flow
- Can supply RS485 communication base on Modbus-RTU protocol
- Can supply corresponding manipulator for operate expediently
- Can customize solar power supply mode, wireless transmission(database server is in China)
Principle:
Ultra sensor is installed on the top of weir/flume( shown as diagram above), sensor emit a bunch of sound wave to liquid surface periodically, when this bunch of wave reach to liquid surface, it will be reflected back and received by sensor, main unit will measure the transmission time (t) of this process. The known sound wave velocity is “V”. d=V*t/2, h=H-d
For the known weir/flume, there is a certain function relationship between the volume flow and the corresponding liquid level value. That is Q= f (h). In main unit, you can set parameter value of weir/flume according to the known weir/flume, the main unit will calculate volume flow automatically during measuring process. Ultrasonic open channel flow meter firstly measures the distance from sensor to the liquid surface, then calculate the liquid level value, then calculate the volume flow. It is important for Installation and commissioning to know this flow meter’s working principle.
Main unit technical data:
Main unit parameter description | |
Weir/flume type | ISO type: Parshall flume (No.1 to 23), rectangular weir(25/50/75/100cm or customize weir width), triangular weir(30°, 45°, 60°, 90°, 120°), customized weir/flume China National type: Parshall flume (No.1 to 25), rectangular weir (25/50/75/100cm or customize weir width), Right-angled triangle weir, customized weir/flume. |
Level resolution | 1 mm |
Level error | 1mm or 0.2%FS @ stable condition |
Ecrã | LCD display with graph and backlight |
Op. Language | Chinese / English (can be selected) |
Parameter setting | Keys operation ( manipulator is option) |
Instant flow display range | 0.000 – 999999L/S or m3/h, m3/min (automatically conversion base on selected flow unit) |
Total flow display Max. value | 99999999.9 m3/h |
Analog output | 4-20mA (corresponding to instant flow) |
Load resistance | 0-500Ω |
Comunicação | RS485 interface, Modbus-RTU protocol |
Saída de relé | Upper limit/lower limit alarm (to control instant flow or liquid level) Pulse output (for accumulated flow, pulse equivalent can be selected) |
Relay switch mode | Normal open / Normal close (can select) |
Relay Number | 6 pcs at most |
Relay specification | 5A 250VAC / 30VDC |
Alimentação eléctrica | 24VDC (±5%) 0.2A; 220VAC(±20%) 0.1A |
Ciclo de medição | 1 second as default (can set) |
Temp. ambiente | -40 to 75℃ |
Material da caixa | ABS |
À prova de intempéries | IP67 |
Cable gland | PG9 / PG11 / PG13.5 |
Montagem | Wall mounted |
Tamanho | 250*185*125 mm |
Sensor technical data:
Sensor parameter description |
|
Level Range | 0.00 ~ 4.00 m, 6.00m, 8.00m, 12.00m, 20.00m, 30.00m, 40.00m |
Blind area | 0.20m |
Operation Temp. | -40 to 70℃ |
À prova de intempéries | IP68 |
Shell material | Option: ABS / PVC / PTFE |
Pressão nominal | 0.2 Mpa |
Comprimento do cabo | Standard configure: 10m, (can extend to 1000m) |
Beam angle | 8°(3db) |
Montagem | Thread, Flanged, Bracket |
Esquema de instalação:
Produtos relacionados
-
Instrumento de caudal
HLS-W312 Ultrasonic Water Meter ( battery powered )
Classificado como 0 em 5Ler mais -
Instrumento de caudal
Medidor de água ultrassónico HLS-W311 (alimentado a pilhas)
Classificado como 0 em 5Ler mais -
Instrumento de caudal
Medidor de caudal eletromagnético de inserção HGCD
Classificado como 0 em 5Ler mais
FAQ
Aresposta : Por favor, envie a sua pergunta ou inquérito para o nosso e-mail: sales@hginstrument.com, nós encaminharemos as perguntas para o engenheiro relacionado.
Aresposta : Por favor comunicar com o departamento de vendas sobre o procedimento de devolução antes de devolver o produto.
Aresposta : O prazo de entrega depende da quantidade encomendada e da especificação do produto. Se a especificação do produto for convencional ( não especial ), o prazo de entrega é de 5 ou 7 dias úteis para quantidade da encomenda ≤ 10 peças; o prazo de entrega é de 2 ou 3 semanas úteis para quantidade de encomenda 15 ~ 30 peças.
Aresposta : por correio, por mar ou por ar
Aresposta : Sim, geralmente a garantia é de um ano.
Aresposta : Do ano 2015 ao ano 2021, as vendas médias anuais são de 350 milhões de RMB (cerca de 54,7 milhões de USD)