HGD Sanitary Electromagnetic Flow Meter

Product name: HGD Sanitary Electromagnetic Flow Meter
The operation temperature of HGD Sanitary Electromagnetic Flow Meter usually not more than 120℃, fluid’s conductivity not less than 5μS/cm.
HGD Sanitary Electromagnetic Flow Meter is applicable for the industry of high health level requirement, such as pharmaceutical, food industry etc.
Hot Tags: About Suyi Group,Flow Instrument,Level Transmitter,water flow meter

Product Description

Technical data of HGD Sanitary Electromagnetic Flow Meter

● Applications: Drinking water, fruit juice, milk, Wine, etc.
● Meter size: DN15 – DN150
● Process connection: Tri-clamp
● Tube material: SS304, SS316
● Electrode: SS316L, Hastelloy B, Hastelloy C, Titanium, Tantalum, Pt/Iridium Alloy, SS with Painting Tungsten Carbide
● Liner: PTFE, FEP, Neoprene, Polyurethane, Hard Rubber, PFA
● Measure accuracy : 1.0%, 0.5%, 0.3%;
● Digital display: instantaneous flow and accumulative flow
● Power supply: 24VDC / 220VAC / 3.6V battery
● Output: 4-20mA, pulse, frequency (RS485, HART, Profibus-DP optional)

 

Wiring Terminal instruction of HGD Sanitary Electromagnetic Flow Meter’s compact converter as follow:

Wiring terminalDescriptionRemark
L 2Connect 220VAC / 24VDC –
L 1Connect 220VAC / 24VDC +
COMCurrent Output Ground for Flow MeasurementUse for wiring of analog Current Output
I +Current Output for Flow Measurement
COMFrequency / Pulse Output GroundUse for wiring of frequency / pulse Output
P+Frequency / Pulse Output for Bi-directional Flow
AHAlarm Output for Upper LimitUse for wiring of alarm Output
ALAlarm Output for Lower Limit
COMAlarm Output Ground (connect with Current Output Ground or Frequency / Pulse Output Ground )
FUSEFuse for Power Supply
T +Communication terminal (RS485 A+)Use for wiring of communication
GRS232 Communication Ground
T –Communication terminal (RS485 B-)
Wiring Terminal instruction of HGD Sanitary Electromagnetic Flow Meter’s remote converter as follow:
Wiring terminalDescriptionRemark
SIG1Signal lFor transducer of remote type
SGNDSignal Ground
SIG2Signal 2
DS1Shielded Exciting  1
DS2Shielded Exciting  2
EXT +Exciting Current “+”
EXT –Exciting Current “-“
VDIN24VDC Connect point (for 2-wire current output)Use for wiring of analog Current Output
IOUTAnalog Current Output
ICOMAnalog Current Output Ground
POUTFlow Frequency (Pulse) OutputUse for wiring of frequency (pulse) Output
PCOMFrequency (Pulse) Output Ground
ALMHUpper Limit Alarm OutputUse for wiring of alarm Output
ALMLLower Limit Alarm Output
ACOMAlarm Output Ground
TRX+Communication terminal (RS485 A+)Use for wiring of communication
TRX-Communication terminal (RS485 B-)
TCOMRS232 Communication Ground
LConnect 220VAC / 24VDC +
NConnect 220VAC / 24VDC –
Parameters list of HGD Sanitary Electromagnetic Flow Meter
ItemParameter wordsFunction descriptionSetting wayRangePassword Grade
1LanguageDisplay languageSelectChinese / English2
2Comm AddresInstrument Communication AddressSetting Value0 ~ 992
3Baud RateInstrument Communication SpeedSelect300 ~ 384002
4Snsr SizePipe line SizeSelect3 ~ 30002
5Flow UnitMeasuring UnitSelectL/h, L/m, L/s, m3/h  m3/min,m3/s2
6Flow RangeMeasure range SettingSetting Value0 ~ 999992
7Flow RspnsMeasure Damping TimeSelect1 ~ 502
8Flow DirectMeasuring Direction SelectionSelectForward / Reverse2
9Flow ZeroFlow Zero AmendmentSetting Value0 ~ ±99992
10Flow CutoffSmall Signal Resection PointSetting Value0 ~ 599.99%2
11Cutoff EnaResection Point Indication

Permission

SelectPermit /Prohibit2
12Total UnitFlow Totalize UnitSelect0.001m3 ~ 1 m3

0.001 L ~ 1 L

2
13SegmaN EnaReverse Output PermissionSelectPermit /Prohibit2
14Analog TypeCurrent Output TypeSelect0 ~ 10 mA / 4 ~ 20mA2
15Pulse TypePulse Output ModeSelectFrequency/Pulse2
16Pulse FactPulse

Unit equivalent

Select0.001m3 ~ 1 m3

0.001 L ~ 1 L

2
17Freque MaxFrequency Output RangeSelect1 ~ 5999 Hz2
18Mtsnsr EnaEmpty pipe Alarm PermissionSelectPermit/Prohibit2
19Mtsnsr TripEmpty pipe Alarm ThresholdSetting Value59999%2
20Alm Hi EnaUpper Limit Alarm PermissionSelectPermit/Prohibit2
21Alm Hi ValUpper Limit Alarm ValueSetting Value000.0 ~ 599.99%2
22Alm Lo EnaLower Limit Alarm PermissionSelectPermit/Prohibit2
23Alm Lo ValLower Limit Alarm ValueSetting Value000.0 ~ 599.99%2
24Sys Alm EnaExcitation Alarm PermissionSelectPermit/Prohibit2
25Clr Sum KeyTotal Flow Zero PasswordSetting Value0 ~ 999993
26Snsr Code1Sensor Code 1User SettingFactory Year Month (0 ~ 99999)4
27Snsr Code2Sensor Code 2User SettingProduct Serial No ( 0 ~ 99999)4
28Field TypeExciting frequency typeSelectType 1, 2, 34
29Sensor FactSensor Factor ValueSetting Value0.0000 ~ 5.99994
30Total PointBatch control volume setSetting Value00000~599994
31Line CRC EnaFlow amend permissionSelectPermit/Prohibit5
32Lineary CRC1Flow amend point 1User Settingsetting according to the velocity5
33Lineary Fact 1Flow amend value 1User Setting0.0000~1.99995
34Lineary CRC2Flow amend point 2User Settingsetting according to the velocity5
35Lineary Fact 2Flow amend value 2User Setting0.0000~1.99995
36Lineary CRC3Flow amend point 3User Settingsetting according to the velocity5
37Lineary Fact 3Flow amend value 3User Setting0.0000~1.99995
38Lineary CRC4Flow amend point 4User Settingsetting according to the velocity5
39Lineary Fact4Flow amend value 4User Setting0.0000~1.99995
40FwdTotal LoForward Total Flow Low LevelRevisable00000 ~ 999995
41FwdTotal HiForward Total Flow High LevelRevisable0000 ~ 99995
42RevTotal LoReverse Total Flow Low LevelRevisable00000 ~ 999995
43RevTotal HiReverse Total Flow High LevelRevisable0000 ~ 99995
44PlsntLmtEnaPeak Restriction PermissionSelectPermit/Prohibit5
45PlsntLmtValPeak Restriction FactorSelect0.010 ~ 0.800 m/s5
46Plsnt DelayPeak Restriction TimeSelect400 ~ 2500 ms5
47Pass Word 1Password grade 1Use Revisable00000 ~ 999995
48Pass Word 2Password grade 2Use Revisable00000 ~ 999995
49Pass Word 3Password grade 3Use Revisable00000 ~ 999995
50Pass Word 4Password grade 4Use Revisable00000 ~ 999995
51Analog ZeroCurrent Zero AmendmentSetting Value0.0000 ~ 1.99995
52Anlg RangeCurrent Full Span AmendmentSetting Value0.0000 ~ 3.99995
53Meter FactCalibration FactorSetting Value0.0000 ~ 5.99995
54MeterCode 1Instrument Code 1Factory SettingFactory Year Month (0 ~ 99999)6
55MeterCode 2Instrument Code 2Factory SettingProduct Serial No. (0~99999)6
Workshop Assembly line
   workshop assembly line

 

Workshop Calibration line

 

Warehouse

warehouse

 

FAQ

Answer : Please send your question or enquiry to our email: sales@hginstrument.com, we will forward the questions to the related engineer.

Answer :  Please communicate with the sales about the return procedure before returning product.

Answer :  The delivery time depends on the order quantity and product specification.  If the product’s specification is conventional ( not special ),  delivery time is 5 or 7 working days for order quantity ≤ 10 pieces;  delivery time is 2 or 3 working weeks for order quantity 15 ~ 30 pieces. 

Answer :  by Courier,  by Sea or by Air

Answer :  Yes,  Generally warranty is one year.

Answer :  From year 2015  to year 2021,  average annual sales is RMB 350 million ( about USD 54.7 million )